18
Turning on and Selecting functions
ELECTRICAL CONNECTION
Before plugging in check that:
• the mains supply corresponds to the value
shown in the specifications table;
• the socket and the mains lead correspond
to the power requirements of the applian-
ce;
• the socket is suited to the plug ,
otherwise have the socket replaced;
• the socket is properly grounded. The
manufactures cannot be held responsible
for any damages due to failure in following
normal safety procedures.
10
Replacement of the power cable must be
carried out by qualified personnel.
AS AIR CONDITIONER
With the unit turned off, the function selector
is in the “O” position. To turn the unit on in air
conditioning mode, proceed as follows:
1. Rotate the function selector knob clockwi-
se:
• Place the large crystal symbol in line
with the reference mark to operate the
unit in air conditioning mode at maximum
fan speed.
• Place the small crystal symbol in line
with the reference mark to operate the
unit in air conditioning mode at minimum
fan speed.
2. Now set the required temperature by rota-
ting the room thermostat knob.
Note
The temperature is not expressed in degrees.
We therefore recommend rotating the room
thermostat knob to the maximum cool posi-
tion. When room temperature has reached
the required level, rotate the thermostat knob
SLOWLY clockwise until the thermostat is acti-
vated, turning the unit off. This programs the
unit to the precise level of comfort required
which will then be automatically maintained
by the thermostat with considerable energy
savings. When regulating the thermostat, the
air conditioning function is temporarily inter-
rupted and the unit continues to operate in
fan only mode.
THIS UNIT EMPLOYS AN EXCLUSIVE CON-
DENSATION RECYCLING SYSTEM TO DISPO-
SE OF EXCESS MOISTURE.
IN NORMAL CONDITIONS, CONDENSA-
TION IS DISPOSED OF AUTOMATICALLY.
WHEN THE HUMIDITY IS PARTICULARLY
HIGH, AN EXCESS OF CONDENSATION
MAY BUILT UP IN THE TANK. WHEN THIS
HAPPENS, THE INDICATOR LIGHT
COMES ON INDICATING THAT THE TANK
SHOULD BE EMPTIED. MAKE SURE THE TANK
IS PUT BACK CORRECTLY OTHERWISE THE
LIGHT WILL REMAIN ON.
12
12
AIR PURIFICATION WITH FAN
Your air conditioning unit has two special high
efficiency electrostatic 3M FILTRETE™ filters.
These filters, active in all modes, filter out
extremely fine particles (down to 0.3 thou-
sands of a millimetre).
If you want to purify the air by ventilating the
room only, rotate the function selector
anticlockwise.
• Place the large symbol in line with the
reference mark to operate the unit in air puri-
fication mode at maximum fan speed.
• Place the small symbol in line with the
reference mark to operate the unit in air puri-
fication mode at minimum fan speed.
13
HOW TO DEHUMIDIFY
When the appliance is working as an air condi-
tioner, it automatically reduces the excess
humidity in the air present in the room. This is eli-
minated through the exhaust tube .
If only the elimination of the excess humidity
in the room is desired without lowering the
temperature, simply turn the function selector
knob in a counter clockwise direction until the
symbol is reached.
Note
In the dehumidifying mode, air colder than
the room temperature will exhaust from the
air exhaust grill. Conversely, air warmer than
room temperature will be exhausted from the
accommodation tube on the back side
of the appliance.
5
9