ATTENTION!
WARNING!
Service hotline
In the case of technical problems, contact our Service hotline. Switzerland:
Tel. 0900 00 1675 (national charges, Swisscom at time of going to print:
CHF2.60/min).Inthecaseofclaimsunderthetermsofguarantee,contact
your sales outlet.
Maintenance
Cleanthesurfaceofthehousingwithasoft,uff-freecloth.Donotuseany
cleaning agents or solvents.
Guarantee
Dexford equipment is produced and tested according to the latest produc-
tion methods. The implementation of carefully chosen materials and highly
developed technologies ensure trouble-free functioning and a long service
life. The terms of guarantee do not apply to the batteries or power packs
usedintheproducts.Theperiodofguaranteeis24monthsfromthedate
ofpurchase.Alldecienciesrelatedtomaterialormanufacturingerrors
within the period of guarantee will be redressed free of charge. Rights to
claims under the terms of guarantee are annulled following tampering by
the purchaser or third parties. Damage caused as the result of improper
handling or operation, normal wear and tear, incorrect positioning or
storage, improper connection or installation or Acts of God and other
externalinuencesareexcludedfromthetermsofguarantee.Inthecase
of complaints, we reserve the right to repair defective parts, replace them
or replace the entire device. Replaced parts or devices become our pro-
perty. Rights to compensation in the case of damage are excluded where
there is no evidence of intent or gross negligence by the manufacturer. If
your device does show signs of a defect within the period of guarantee,
please contact the sales outlet where you purchased the Dexford device,
producing the purchase receipt as evidence. All claims under the terms
of guarantee in accordance with this agreement can only be asserted at
the sales outlet. No claims under the terms of guarantee can be asserted
after a period of two years from the date of purchase and hand-over of the
product.
Disposal
In order to dispose of your device, take it to a collection point
provided by your local public waste authorities (e.g. recycling
centre). According to the laws on the disposal of electronic and
electrical devices, owners are obliged to dispose of old electronic
and electrical devices in a separate waste container. The adjacent
symbol indicates that the device must not be disposed of in normal
domestic waste!
You are legally obliged to dispose of power packs and batteries
at the point of sale or in the corresponding containers provided at
collection points by local public waste authorities. Disposal is free of
charge. The symbols indicate that the batteries must not be disposed
of in normal domestic waste and that they must be brought to collection
points provided by local public waste authorities. Packaging materials must
be disposed of according to local regulations.
Declaration of Conformity
ThisdevicefullstherequirementsstipulatedintheDirective
1999/5/EConradioequipmentandtelecommunicationsterminal
equipmentandthemutualrecognitionoftheirconformity.Conformi-
tywiththeabovementioneddirectiveisconrmedbytheCEmarkonthe
device.ToviewthecompleteDeclarationofConformity,pleaserefertothe
free download available on our web site www.dexford.com.
ENGLISH
WSRC 2254
Weather Station with wireless-thermometer
and radio clock
Operating Instructions
Please read and observe the following information and keep the
operating manual nearby for future reference!
Thermo-hygro sensor (WRS)
Safety information
Only use batteries of the same type!
Always treat batteries with due care and attention and only use
batteries as described.
Never use standard and rechargeable batteries together. Never use
rechargeable batteries or standard batteries with different capacities or
charge statuses together. Never use standard or rechargeable batteries
which are damaged.
Risk of suffocation through small objects, packaging and protective foil!
Keep children away from the product and its packaging!
Risks to health and the environment from batteries!
Never open, damage or swallow batteries or allow them to pollute the
environment. They could contain toxic and ecologically harmful heavy
metals.
Preventexposuretoenvironmentalinuences,e.g.smoke,dust,
vibration, chemicals, moisture, heat and direct sunlight.
Onlyallowrepairstobecompletedbyqualiedpersonnel.
Package contents
Weather station main unit, Thermo-hygro sensor, Operating manual
Display icons and operating elements
1 Weather Forecast
2 Outdoorhumiditytrend,
3 Outdoor humidity
4 Indoorhumidity
5 MoonPhase
6 Alarm
7 Time
8 Day of week
9 RCCsymbol(radioclock),„S“=summertime(+1hour)
10 Month
11 Date
12 Livingspacehumidity(Comfortable,dry,humid)
13 Indoor temperature
14 RFsymbolandChannel
15 Indoor temperature trend,
16 Outdoor temperature
17 Outdoor temperature
18 Outdoor humidity
19 Battery compartment (Back side)
A MODE
B ALARM
C +
D CHANNEL(Resetoutdoortemperaturememoriespress3sec.)
E -
F SNOOZE/LIGHT
a Changefrom°C/°F
b Changechannel
STARTING UP
After inserting the batteries, the main unit will connect with the radio
transmitter(WRS)byRFsignal.TheRFsignal(14)symbolattheout
areawillash.
This process takes about 3 minutes. Then the display shows the
outdoor temperature and humidity. In case of failure of reception, pls
press“CHANNEL“(D)formorethan3secondstoreceiveagain.
The weather station is capable of receiving up to 3 different channels.
Selectthechannelnumber(1,2,or3)bypressingthe“b”switch.
The weather station will scan the 3 channels automatically.
Selectthechannelnumber(1,2,or3)bypressingthe“Channel”button
(D) on weather station.
TheautomaticreceivingoftheDCFradiosignal(DCF77,Timesignal
frequency 77,5 kHz) begins after 3 minutes of outdoor RF reception.
ThisDCFreceptionprocessisgoingon,theashingsymbol“radio
tower“ (9) appears in the time display area at the same time.
ATTENTION: Please note all other clock / weather station settings
seize to function when the clock is in RCC synchronization mode.
Once radio signal receiving is successful, the display shows the symbol
“radiotower“(9)continuously.Noashing.Onesynchronisationper
dayissufcienttokeepthetimedisplayaccuracyat1second.
Pleaseobserveaminimaldistanceof2.5mtosourcesofinterference
such as televisions or computer screens.
MANUAL SET-UP
(The clock automatically changes from set-up mode to time display mode if
no keys are pressed for 8 seconds.)
Press and hold key “MODE“ for 3 seconds.
Thedisplayforthetimezoneisashing.
Use “+“ and “-“ to select
Press “MODE“toconrm.
Thedisplayforthehourisashing
Use “+“ and “-“ to select
Press “MODE“toconrm.
Thedisplayfortheminutesisashing
Use “+“ and “-“ to select
Press “MODE“toconrm.
Thedisplayfortheyearisashing.
Use “+“ and “-“ to select
Press “MODE“toconrm.
Thedisplayforthemonthisashing.
Use “+“ and “-“ to select
17
18
a
b
Press “MODE“toconrm.
Thedisplayforthedateisashing.
Use “+“ and “-“ to select
Press “MODE“toconrm.
Thelanguageselectionforthedisplayoftheweekdaysisashing.
GE = German; EN = English; IT = Italian; FR = French; NE = Dutch;
ES = Spanish; DA = Danish
Use “+“ and “-“ to select
Press “MODE“toconrm.
Alarm set-up
Press and hold the key “ALARM“ for 3 seconds
Thehourdisplayofthealarmtimeisashing.
Use “+“ and “-“ to select
Press “ALARM“toconrm.
Theminutedisplayofthealarmtimeisashing.
Use “+“ and “-“ to select
Press “ALARM“toconrm.
Alarm on/off
Press “ALARM”toactivatethealarm
Thealarmsoundsfor2minutesifnokeyispressedtostopit.Otherwise,
thealarmchangesautomaticallyafter2minutesintothe”Snooze“function
Snooze function
Press the key “SNOOZE/LIGHT“, while the alarm sounds, to activate
the snooze function. If the snooze function is activated, alarm symbol is
ashing.Thealarmrepeatafter5minutes.
The snooze function can be stopped by pressing any key.
Illumination
Press the key “SNOOZE/LIGHT“ to activate the display illumination for
8 seconds.
Switch between °C / °F
Press the key “-“
WEATHER FORECAST
Sunny Slightly Cloudy Cloudy Rainy
Theweatherstationanalyzestheweatherpatternsfromthepast24hours
todeterminetheforecastforthenext12–24hoursforanareawithinara-
dius of approximately 30-50 km. The weather forecast is only for reference
and domestic use. Accuracy rate might be lower in extreme conditions.
Moon phase display
The weather station uses saved data to determine the moon phases. So it
is not necessary to manually enter data. There are 8 moon phases appear.
Feature Value
WSRC2254
W x H x D 70x160x32mm
Weight 178 g (without battery)
Signal frequency 433MHz
Power 2x1,5VAA,notincluded
Temperature range -20~+50°C
Humidity range 20~95%
Thermo-hygro sensor (WRS) max. 30 meters in open area
W x H x D 60x100x25mm
Weight 52g(withoutbattery)
Power 2x1,5VAAA,notincluded
Temperature range -20~+60°C
Humidity range 20~95%
Technical data (All rights reserved)
The radio signal sender (DCF) coverage up to 1500km distance to
Frankfurt/Main. If, due to bad reception,or no RCC automatic time
reception is possible, follow the steps below manually.
ATTENTION: Please note all other clock / weather station settings
seize to function when the clock is in RCC synchronization mode.
The most important is to quit the receiption of radio controlled sig-
nal by holding “-” for 3 seconds in case of the “radio tower”symbol
ashing before set-up.
1
16
15
12
14
13
8
10
11
9
A
B
D
C
F 19
E
2
3
4
5
6
7