716643
16
Zoom out
Zoom in
Vorherige Seite
1/41
Nächste Seite
www.dickinsonmarine.com ~ info@dickinsonmarine.com
Form#7.2-229 Issue#2
16
Once the valve is full of fuel and the pressure has been reached the fuel
pump will still continue to tick, but less frequent. Once the pressure drops in
the valve the pump will then begin to tick more frequent depending on the
demand of fuel from the valve. To lessen the noise of the pump pulsing, a
rubber backing can be installed.
The pump should be included in a control circuit with a 2 amp fuse so it can
be turned off when the heater is not in use. NOTE: If the power to the pump
is shut off, the fuel could still flow through to the pump by way of siphon.
The flow of fuel should be turned off using the shut-off valve near the heater
as well as the oil metering valve.
The pumps can be installed with fuel inlets and outlets up or down, however
mounting the pump with the fuel inlet (spout looking side) on top will give
the pump extra pressure and is easier to clean. The pump will need to be
primed the first time only to remove air in the fuel line. There are 3 check
valves in the pump to prevent the back flow of fuel, so the pump should stay
primed. If the pump does not stay primed then 1 of the check valves in the
pump needs to be cleaned
The pump should be installed in a ventilated area and not near a hot exhaust.
Connect the ground to a negative battery. This pump is not recommended for
gasoline.
Walbro FRD-2 Fuel Pump Upgrade
To upgrade a Walbro FRD-2 (part#20-000) to a Heavty Duty pump
(part#20-002) a factory spring & regulator must be installed. If you find you
are not getting fuel to the valve with the FRD-2 standard pump you may
need the stronger pump with the stronger pressure. Please contact Dickinson
to order a stronger spring & regulator. info@dickinsonmarine.com
Once you have received a stronger spring and regulator from Dickinson, you
can upgrade your pump to a stronger pressure. Unscrew the 3 torx screws (t-
20) and with twisting the lid back and forth, pull it straight back off. Note
the pump plunger, spring, check valve, and a very small amount of fuel will
drop out if installed as per diagram. Place the check valve as shown in the
diagram on top of the heavier replacement spring, and the spring on top of
the pump plunger and push it back into the pump body holding it in with a
finger. Note the magnetic part of the plunger is on the opposite end of the
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dickinson Marine Alaska wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info