6. Return the tank to the sump, with the tank cap facing down and - see Fig. 10.
7. Gently place the metalbed back into position.
CLEANING
WarningAlways press Switch ‘A to the ‘OFF’ (0) position - see Fig. 11 and disconnect from the power supply before
cleaning the re.
We recommend cleaning the following components once every 2 weeks, particularly in hard water areas:-
Water Tank, Sump, Nozzle, Tank cap and seal, Air lter.
For general cleaning use a soft clean duster – never use abrasive cleaners.
To remove any accumulation of dust or uff, the soft brush attachment of a vacuum cleaner should occasionally be
used.
Water tank
1. Lift the metalbed and place carefully on the table/worktop - see Fig. 3.
2. Remove the water tank, as described earlier - see Fig. 6, put into sink , unscrew cap anti-clockwise - see Fig. 9
and empty water.
3. Using the supplied brush gently rub the inside surfaces of the cap, paying particular attention to the rubber ring in
the outer groove and the centre rubber seal.
4. Put a small quantity of washing up liquid into the tank, ret the cap and shake well, rinse out until all traces of
washing up liquid are gone.
5. Rell with decalcied/ltered tap water only, replace the cap (clockwise) , do not overtighten - see Fig. 10.
6. Gently place the metalbed back into position.
Sump
1. Lift the metalbed and place carefully on the table/worktop - see Fig. 3.
2. Press Switch ‘A’ to the ‘OFF’ (0) position -
3. Remove the water tank by lifting upwards and outwards - see Fig. 6.
4. Remove the nozzle by unclipping (1) and lifting upwards (2) - see Fig. 7
5. Disconnect the transducer (1) and feed/pull the connector underneath the LED’s (2) - see Fig. 15.
6. Gently lift up the sump, taking care to keep level so as not to spill any water. Sit the assembly in the sink.
7. Lift out the transducer and carefully tilt, so that the liquid drains out of the sump.
8. Put a small amount of washing up liquid into the sump, and using the supplied brush, gently clean all surfaces in the
sump and gently clean the transducer including the metal discs located in the top grooved surface - see Fig. 16.
10. When cleaned, thoroughly rinse the sump with clean water to remove all traces of washing up liquid.
11. Clean the Nozzle with the brush and ush out thoroughly with water - see Fig. 17.
12. Reverse the above steps to reassemble.
Air lter
1. Lift the metal bed and place carefully on the table/worktop - see Fig. 3.
2. Gently slide the air lter upwards out of its plastic holder - see Fig. 12.
3. Gently rinse with water in the sink and dry with fabric towel before returning.
4. Replace the lter making sure that the coarse black lter is facing the front of the re.
5. Gently place the metalbed back into position.
4
Additional Information
AFTER SALES SERVICE
Your product is guaranteed for 2 years from the date of purchase. Within this period, we undertake to repair or
exchange this product free of charge (excluding transducer disc, subject to availability & lifetime subject to regular
maintenance) provided it has been installed and operated in accordance with these instructions. Your rights under this
guarantee are additional to your statutory rights, which in turn are not affected by this guarantee.
RECYCLING
For electrical products sold within the European Community - At the end of the electrical products useful life
it not be disposed of with household waste. Please recycle where facilities exist. Check with your Local
Authority or retailer for recycling advice in your country.
PATENT / PATENT APPLICATION
Products within the Optimyst range are protected by one or more of the following patents and patent applications:
Great Britain GB 2402206, GB 2460259, GB 2460453 , GB 2418014, GB 2465738, GB 2449925, GB 2465537 , GB
2455277 , GB1020534.2, GB1020537.5, GB1110987.3
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

dimplex-cas250

Suche zurücksetzen

  • muss das Wasser aus dem Sammelbehälter entfernt werden zum Wechsel des Wendlers bei DimplexCS250 Eingereicht am 17-11-2024 11:51

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex CAS250 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info