Saving energy
Set the desired warm water temperature directly on the
flow-through heater.
Mixing with cold water at the armature for water that is too
hot consumes unnecessarily water and energy.
At approx. 40 °C (temperature selection position
) the
unit operates most economically.
Cleaning
Simply wipe the appliance with a damp cloth.
Do not use intensive or abrasive cleaning agents.
A fault, what to do?
If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy
the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service
personnel.
Fault Cause Solution Who
Water flow-rate is too low. The filter in either the water tap or
the showerhead is clogged
Remove the filter and either
clean it or descale it.
Customer
The filter in the corner regulating
valve is clogged.
Get a servicing expert to clean the
filter.
Servicing
expert
The filter upstream from the check
valve in the cold water supply inlet
is clogged.
Remove the filter and either
clean it or descale it.
Servicing
expert
The desired water temperature is
not reached.
The continuous-flow heater is
connected to a thermostatically-
controlled water tap.
Set the temperature on the continu-
ous-flow heater to “max”.
Customer
The power limit has been reached.
Water flow-rate is too high and/or
the cold water supply temperature
is too low.
Reduce the flow-rate at the water
tap supply.
Customer
By a qualified professional:
use the angle valve to regulate the
flow-rate.
Check the flow-rate limiter or re-
place it with a smaller one.
Servicing
expert
The water is not sufficiently warm. The fuse in the house electrical in-
stallation has tripped/blown.
Check the fuse in the house electri-
cal installation.
Customer
The appliance‘s automatic circuit
breaker has been tripped.
Get the appliance‘s automatic cir-
cuit breaker checked by an electri-
cian. Check the permissible supply
temperature.
Servicing
expert
The power limit has been reached.
Water flow-rate is too high and/or
the cold water supply temperature
is too low.
By a qualified professional:
use the angle valve to regulate the
flow-rate.
Check the flow-rate limiter or re-
place it with a smaller one.
Servicing
expert
From time to time, cold water
flows out.
The air sensor in the appliance de-
tects air in the water and momen-
tarily switches the heating element
off.
After a few seconds, the continu-
ous-flow heater automatically goes
back into operation.
Continu-
ous-flow
heater au-
tomatically
resolves
problem
Winter operation:
The desired water temperature
leaving the tap is no longer
reached.
The supply temperature has
reduced.
Reduce the water flow on the taps
until the desired water temperature
is reached.
Customer
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex DEE 2103 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info