www.glendimplex.de 452168.66.05a · FD 0104 EN-11
HPL 9S-TU(R)W - HPL 18S-TU(R)W English
for domestic hot water inches 1“ AG 1“ AG 1“ AG
for circulation pipe inches 3/4“ IG 3/4“ IG 3/4“ IG
for expansion vessel inches 1“ AG/FL 1“ AG/FL 1“ AG/FL
6.12 Anode diameter HWK mm 33 33 33
6.13 Anode length HWK mm 690 690 690
6.14 Anode connection thread HWK inches 1 1/4“ IG 1 1/4“ IG 1 1/4“ IG
6.15 Weight of the transport unit(s)
incl. packaging HWK kg 210 210 210
7 Electrical connection
7.1 Supply voltage / fusing / RCD type 3~/N/PE 400 V (50 Hz) /
C10 A / A
3~/N/PE 400 V (50 Hz) /
C10 A / A
3~/N/PE 400 V (50 Hz) /
C13 A / B
7.2 Control voltage / fusing by WPM 1~/N/PE 230 V (50 Hz) /
4 AT
1~/N/PE 230 V (50 Hz) /
4 AT
1~/N/PE 230 V (50 Hz) /
4 AT
7.3 Degree of protection according to EN 60529 IP 24 IP 24 IP 24
7.4 Starting current limiter Soft starter Soft starter Soft starter
7.5 Rotary field monitoring Yes Yes Yes
7.6 Starting current with soft starter A 21 19 21
7.7 Nominal power consumption A2/W35/ max. power consumption 4 kW 1.7 / 3.3 2.38 / 4.0 3.24 / 6.8
7.8 Nominal current A2 /W35 / cos  A / --- 3.1 / 0.8 4.3 / 0.8 5.9 / 0.8
7.9 Power consumption of compressor protection
(per compressor) W / ---
70 / thermostatically
controlled
70 / thermostatically
controlled
70 / thermostatically
controlled
7.10 Power consumption of fan W up to 100 up to 150 up to 200
7.11 Control voltage, fusing HWK
7.12 Supply voltage / fusing
( P = 3.5 kW) HWK
1~ / N / PE 230V (50Hz) /
B63A
1~ / N / PE 230V (50Hz) /
B63A
1~ / N / PE 230V (50Hz) /
B63A
HWK 3~ / N / PE 400V (50Hz) /
B25A
3~ / N / PE 400V (50Hz) /
B25A
3~ / N / PE 400V (50Hz) /
B25A
Supply voltage / fusing
( P = 3.5 kW) HWK
1~ / N / PE 230V (50Hz) /
B16A
1~ / N / PE 230V (50Hz) /
B16A
1~ / N / PE 230V (50Hz) /
B16A
3~ / N / PE 400V (50Hz) /
B10A
3~ / N / PE 400V (50Hz) /
B10A
3~ / N / PE 400V (50Hz) /
B10A
8 Complies with the European safety regulations 11 11 11
9 Additional model features
9.1 Type of defrosting Reverse circulation Reverse circulation Reverse circulation
9.2 Frost protection, condensate tray /
Water in device protected against freezing12 Yes Yes Yes
9.3 Maximum operating pressure (heat sink) bar 3.0 3.0 3.0
9.4 Energy efficiency class / energy efficiency (low temperature) A++ / 177 % A++ / 173 % A++ / 168 %
9.5 Energy efficiency class / energy efficiency (mean temperature) A++ / 127 % A++ / 128 % A++ / 133 %
10 Heat output COP 4
10.1 Heat output / COP EN 14511 EN 14511 EN 14511
Performance level 121212
at A-7 / W35 kW / --- 5.5 / 3.3 --- 7.2 / 3.2 --- 5.6 / 3.3 10.5 / 3.2
at A2 / W35 kW / --- 7.2 / 4.3 --- 9.5 /
4.1(4.3)13 --- 7.3 / 4.3 12.3 / 3.9
(4.0)13
at A7 / W35 kW / --- 8.4 / 4.9 --- 11.3 / 4.8 --- 8.4 / 5.0
at A7 / W45 kW / --- 8.2 / 3.8 --- 10.8 / 3.9 --- 8.1 / 3.9
at A7 / W55 kW / --- 8.0 / 3.0 --- 10.0 / 3.1 --- 7.7 / 3.2
at A10 / W35 kW / --- 8.9 / 5.3 --- 12.0 / 5.1 --- 8.8 / 5.4
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? t
2. Operation with 2 compressors
3. Operation with 1 comressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in
particular the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care,
commissioning and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/
W35: outside air temperature 7 °C and heating water flow temperature 35 °C.
5. Standard nominal flow only possible with an electronically controlled circulating pump with actuation via heat pump manager.
6. The heat output and COP is reduced by approx. 5 % in lower operation
7. When the optional weather protection hood (accessory) is used. the sound pressure level in outlet direction is reduced by 3 dB(A).
8. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
9. condition as delivered 6 kw
10.Note that additional space is required for pipe connections, operation and maintenance.
11.See CE declaration of conformity
12.The heat circulating pump and the heat pump manager must always be ready for operation.
13.The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
35

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex HPL 9S-TUW wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info