LAK 3IMR - LAK 14ITR English
6.6 Starting current A 1.1 1.2 1.2 5,9 1.3
6.7 Nominal power consumption at A7/W35 /
max. consumption 5 6kW 0.65 / 4.471.17 / 8.3972.11 / 9.4173.31 / 11,69 73.39 / 12.28 7
6.8 Nominal current at A7/W35 / cos A / -- 2.8 / 0.99 5.14 / 0.99 9.27 / 0.99 14,54 / 0.99 4.94 / 0.99
6.9 Nominal power consumption A2 / W35 60.8 1.41 1.91 3.69 3.50
6.10 Power consumption of compressor protection
(per compressor) W -- -- -- -- --
6.11 Power consumption of fan W 43 124 124 248 248
7 Complies with the European safety regulations 88888
8 Additional model features
8.1 Type of defrosting Reverse circula-
tion
Reverse circula-
tion
Reverse circula-
tion
Reverse circula-
tion
Reverse circula-
tion
8.2 Condensate tray frost protection /
Water in device is protected from freezing 9No / Yes No / Yes No / Yes Yes/ Yes Yes/ Yes
8.3 Max. operating overpressure (heat source/heat sink) bar 3.0 3.0 3.0 3.0 3.0
9 Heat output / coefficients of performance (COP)
9.1 Heat output / COP5EN 14511 EN 14511 EN 14511 EN 14511
at A-15 / W35 kW / --- 10 2.3 / 2.1 3.6 / 2.3 5.2 / 2.3 10.9 / 2.4 10.6 / 2.4
kW / --- 62.3 / 2.1 3.6 / 2.3 5.2 / 2.3 10.9 / 2.4 10.8 / 2.4
at A-7 / W35 kW / --- 10 2.5 / 2.6 4.2 / 2.8 6.3 / 2.4 13.1 / 2..7 13.9 / 2.9
kW / --- 62.5 / 2.6 4.2 / 2.8 6.3 / 2.4 13.1 / 2.7 13.9 / 2.9
at A-7 / W55 kW / --- 10 2.0 / 1.7 2.9 / 1.8 4.2 / 1.7 9.0 / 1.7 11.3 / 2.1
kW / --- 62.0 / 1.7 2.9 / 1.8 4.2 / 1.7 9.0 / 1.7 11.3 / 2.1
at A2 / W35 kW / --- 10 2.6 / 3.2 4.8 / 3.4 5.3 / 3.6 10.7 / 3.3 10.5 / 3.6
kW / --- 62.6 / 3.2 4.8 / 3.4 6.2 / 3.2 12.3 / 3.3 11.0 / 3.2
at A7 / W35 kW / --- 10 3.0 / 4.6 5.6 / 4.8 5.6 / 4.8 10.2 / 4.4 10.6 / 4.1
kW / --- 63.0 / 4.6 5.6 / 4.8 9.0 / 4.3 14.6 / 4.4 14.7 / 4.3
at A7 / W45 kW / --- 10 2.8 / 3.2 5.4 / 3.4 5.4 / 3.4 9.1 / 3.8 9.8 / 3.7
kW / --- 62.8 / 3.2 5.4 / 3.4 8.3 / 3.3 14.0 / 3.5 13.9 / 3.3
at A7 / W55 kW / --- 10 2.5 / 2.6 5.1 / 2.9 5.1 / 2.9 8,7 / 2.9 8.8 / 2.9
kW / --- 62.5 / 2.6 5.1 / 2.9 6.2 / 2.6 12.9 /2.9 13.2 / 2.7
at A10 / W35 kW / --- 10 3.2 / 4.8 6.0 / 5.1 6,0 / 5.1 10.8 / 4.6 11.3 / 4.5
kW / --- 63.2 / 4.8 6.0 / 5.1 9.6 / 4.5 14.9 / 4.4 15.7 / 4.3
at A20 / W35 kW / --- 10 3.6 / 4.0 7.3 / 5.8 7.3 / 5.8 13.1 / 5.7 13.9 / 5.5
kW / --- 63.6 / 4.0 7.3 / 5.8 10.8 / 5.3 18.8 / 5.7 22.3 / 5.1
at A20/ W55 kW / --- 10 2.2 / 3.1 5.7 / 3.4 5.7 / 3.4 10.6 / 3.6 10.8 / 3.8
kW / --- 62.2 / 3.1 5.7 / 3.4 8.4 / 3.2 16.9 / 3.7 16.2 / 3.6
9.2 Cooling capacity / COP
at A27 / W7 kW / --- 62.4 / 3.8 6.5 / 3.3 6.5 / 3,3 12.4 / 3.1 12.9 / 3.0
at A27 / W18 kW / --- 63.2 / 4.6 8.7 / 4.2 8.7 / 4.2 16.4 / 3.8 17.1 / 3.7
at A35 / W7 kW / --- 62.3 / 3.0 6.2 / 2.6 6.2 / 2.6 11.8 / 2.5 12.3 / 2.5
at A35 / W18 kW / --- 63.0 / 4.0 9.0 / 3.4 9.0 / 3.4 14.0 / 3.1 15.5 / 3.3
1. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3 dB (A).
2. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation at 35°C flow temperature.
The specified sound pressure level is the free sound area level. The measured value can deviate by up to 16 dB(A) depending on the installation location.
3. Please note that additional space is required for pipe connections, operation and maintenance.
4. Factory default 6 kW
5. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
the regulation should be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning and operation can be found
in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C and heating
water flow temperature 35 °C.
6. Maximum heating/cooling output
7. Max. intake incl. pipe heating and immersion heater (state of supply)
8. See CE declaration of conformity
9. The heat circulating pump and the heat pump controller must always be ready for operation.
10.COP-optimised operation
45

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex LAK 14IMR wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info