798483
17
Zoom out
Zoom in
Vorherige Seite
1/44
Nächste Seite
www.dimplex.de E-7
English
12
12 Device Information
Device information for brine-to-water heat pumps for heating purposes
1 Type and order code SI 5US SI 7US SI 9US SI 11US SI 14US
2Design
2.1 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20 IP20
2.2 Installation Location Indoors Indoors Indoors Indoors Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow °C Up to 55 Up to 55 Up to 55 Up to 55 Up to 55
Brine (heat source) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25
Antifreeze Monoethyl-
ene glycol
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Minimum brine concentration (-13 °C freezing temperature) 25% 25% 25% 25% 25%
3.2 Temperature spread
of heating water (flow/return flow) at B0 / W35 K 9.9 9.9 10.4 9.5 9.4
3.3 Heat output / COP at B-5 / W55 1kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
4.1 / 1.8 5.6 / 1.9 7.4 / 2.0 9.4 / 2.0 11.7 / 2.1
at B0 / W50 1kW / --- 4.9 / 2.8 6.4 / 2.7 8.7 / 2.7 10.5 / 2.6 13.5 / 2.8
at B0 / W35 1kW / --- 5.2 / 4.0 6.9 / 4.0 9.1 / 4.0 11.0 / 4.0 14.2 / 4.0
3.4 Sound power level dB(A) 54 55 56 56 56
3.5 Heating water flow with an internal pressure differential of m³/h / Pa 0.45 / 1900 0.6 / 3300 0.75 / 2300 1.0 / 4100 1.3 / 4800
3.6 Brine throughput with an internal pressure differential
(heat source) of m³/h / Pa 1.2 / 16000 1.7 / 29500 2.3 / 25000 3.0 / 24000 3.5 / 20000
3.7 Refrigerant; total filling weight type / kg R407C / 0.9 R407C / 0.8 R407C / 1.25 R407C / 1.25 R407C / 1.5
4 Dimensions, connections and weight
4.1 Device dimensions without connections 2H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
800 × 600 ×
450
800 × 600 ×
450
800 × 600 ×
450
800 × 600 ×
450
800 × 600 ×
450
4.2 Device connections to heating system Inch G 1¼"
external
G 1¼"
external
G 1¼"
external
G 1¼"
external
G 1¼"
external
4.3 Device connections to heat source Inch G 1¼"
external
G 1¼"
external
G 1¼"
external
G 1¼"
external
G 1¼"
external
4.4 Weight of the transportable unit(s) incl. packing kg 95 98 104 108 120
5 Electrical Connection
5.1 Nominal voltage; fuse protection V / A 400 / 16 400 / 16 400 / 16 400 / 16 400 / 16
5.2 Nominal power consumption 1 B0 W35 kW 1.3 1.67 2.21 2.75 3.56
5.3 Starting current with soft starter A 22
(without SS)
30
(without SS) 15 26 26
5.4 Nominal current B0 W35 / cos ϕA / --- 2.35 / 0.8 3.0 / 0.8 4.0 / 0.8 5.0 / 0.8 6.4 / 0.8
6 Complies with the European safety regulations 3
3. See CE declaration of conformity
3 3 3 3
7 Additional model features
7.1 Water in device protected against freezing 4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes Yes Yes Yes Yes
7.2 Performance levels 11111
7.3 Controller internal/external Internal Internal Internal Internal Internal
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex SI 9US wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info