Commissioning English
9. Commissioning
9.1. Minimum tests
After the heating device has been fully installed and
connected, you can carry out a check to make sure it
is working correctly.
The following minimum tests must be carried out:
Isolation test with a voltage of at least 500 V. The
isolation resistance must be at least 0.5 MΩ.
Measurement of the power consumption.
Alternatively, a cold resistance measurement can
be carried out.
9.2. Re-installation
If a device has already been in operation, disassem-
bled and set up at a different location, all commission-
ing checks must be carried out again before heating
operation.
During the first charge of the storage heater after in-
stallation, the entire process, starting with the cold
state (room temperature) to the switch-off of the load
controller, must be monitored by a qualified specialist.
Determine the amount of energy used by the heating
device during this process in kWh. This must not be
more than 125% of the rated charging stated on the
rating plate.
NOTE
During installation, check that the thermal insulation
was not damaged during transport.
Damaged thermal insulation must be replaced with an
identical part before the heating device is used again!
9.3. Installer menu
The commissioning of the storage heater by the spe-
cialist takes place via the installer menu. First, the fol-
lowing entries must be made:
Current time, date
DST = summer/winter time switch,
Key tone on/off.
Once the entries have been made, the user main
menu appears. The timer times listed below are set at
the factory. They can be adjusted at any time.
The functions described below can be set in the in-
staller menu.
Calling up the installer menu
Hold down the Menu key. The display initially
switches to the CHARGING menu. Continue to hold
the key (for approx. 3 seconds in total). The display
switches to the main menu.
P9 - operation on central charge control
NOTE
No setting is required if the device is operated without
central charge control.
Press and hold the MENU, ENTER and BACK key
for approx. three seconds. PIN code 0000 flashes.
Confirm the PIN code four times with the ENTER
key. Display P9 flashes.
Select display P9. P9 flashes.
Press the ENTER key. OFF flashes.
Use the   keys to select ON. ON flashes.
Press the ENTER key. Display DC flashes.
NOTE
Display DC/AC stands for the control signal of the
central control device. Either DC or AC must be se-
lected depending on the type used.
Comfort 1 Comfort 2 Comfort 3 Comfort 4
06:30 -
09:30
11:00 -
13:00
15:00 -
17:00
18:00 -
21:00
No. Function Explanation
P9 Central charge
control
Yes/No,
If yes: AC/DC,
If AC: Duty cycle in percent
P10
External room
temperature con-
troller
Yes/No
P11 auxiliary heating Yes/No
P12 Release signal currently without function
P13 Release manual
Define time window for
manual release.
See “P12 - release signal”
on page 21.
P14
Reaction to failing
central charge
control signal
100% or 0% charge in case
of failing signal.
No. Function Explanation
45

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex VFE40K wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info