Fitting panel – After Installation
The Back Panel can also be change after the product has been installed, a person of suitable
competency is required to carry out this task. Please follow the steps below.
1. Unplug product from Power Supply and remove front trim on unit. See Fig. 2
2. Remove Front Glass from product and store in a safe place. (A suction cup is provided to help
remove/place the front glass.) See Fig. 6
3. Remove Fuelbed fixing screws, then remove Fuelbed. (Fig. 7)
4. Remove both Side Glasses by moving them out at the bottom, then sliding out to remove. Store
these in a safe place. (Fig. 8).
5. Remove plastic Inner Screen by tilting it from the base. (Fig.9)
6. Remove Back Inner Panel bracket (Fig. 10A), Inner Back panel can then be tilted and removed
from its housing. (Fig. 10B)
7. Replace with new Back Inner Panel, and reverse the steps set out above, to re-assemble the
product. Ensure Inner screen is reassembled correctly. (Smooth mirrored finish to face the front of
the product.)
Step 3: Installing the Product
CAUTION: Two people will be required for various steps of this procedure.
This product is designed to be installed into existing block wall or a custom-built studded wall
structure. Please consult a competent installer before undertaking this to ensure a safe and
secure installation. If installing into an existing chimney or flue, please ensure that the chimney or
flue is blocked o. This is to prevent up-draughts aecting product operation.
Electrical Requirements
NOTE: A dedicated, properly fused 13 Amp circuit is required, rated for the appropriate voltage
(230-240V). An isolation switch should also be incorporated in cases where the product plug is
inaccessible after installation.
WARNING: Construction and wiring must comply with local building codes and other applicable
regulations to reduce the risk of fire, electric shock and injury to persons.
WARNING: To reduce the risk of fire, electric shock or injury to persons, always use a licensed
electrician.
1. Using the product dimensions (Fig. 11), build a suitable structure for the product to fit into.
Ensure that, when installed, the product is within 1m of a power outlet. Please refer to Electrical
Requirements section above for more details.
It is recommended that the base of the unit is installed between 200mm and 800mm from the
floor. This is to maintain an optimised viewing angle of the fire eect. (See Fig. 12)
The product must not bear the weight of the finished wall located above it. Consider the use of a
lintel for appropriate support.
2.Using any combination of the three fixing methods (Fig. 13 a,b,c), fix the product to its supporting
structure.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex Vivente VVT75 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Dimplex Vivente VVT75

Dimplex Vivente VVT75 Bedienungsanleitung - Holländisch, Dänisch, Polnisch, Türkisch, Norwegisch - 68 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info