798196
3
Zoom out
Zoom in
Vorherige Seite
1/110
Nächste Seite
OPERATING WARNINGS
IMPORTANT: Remember to observe all safety warnings and precautions when operating
the heater on the automatic or timer modes, either attended or unattended since a fire
risk exists when the heater is accidentally covered or obstructed.
Mains cables are not provided with this heater.
CAUTION: Do not use if either of the heater’s mains power leads become damaged. If
the supply cord is damaged it must be replaced by the installer or an approved Dimplex
service partner.
Curtains must not come to within 250mm of the top of the heater.
Do not sit or stand on the heater.
Do not place objects in contact with the heater.
To maintain stability, it is essential that the heater is placed on a level surface and care
should be taken to avoid irregular surfaces, such as may result from carpets or tiled
surrounds partially protruding under the heater.
ELECTRICAL INSTALLATION
The installation of the heater should be carried out by trained personnel.
WARNING - Minimum clearances and IP zone requirements must be adhered to in
accordance with the current wiring regulations.
WARNING - The electrical installation of this heater must be carried out by a suitably
qualified or trained electrician, and be in strict accordance with current wiring Regulations.
The peak supply must be connected via a switched fused spur with a fuse rated suitably
for the appliances flex, the o-peak supply , via a 20A double pole switch. Failure to
follow these instructions will mean that the manufacturer’s instructions have not been
adhered to. THERE ARE NO EXCEPTIONS.
• This heater must be earthed
• Not suitable for connection via a plug top
• Do not locate the heater immediately above or below a fixed electrical point i.e. socket
outlet.
This appliance is intended for installation to a single phase supply only and is not suitable
for connection to 3 phase supplies.
The heater is not fitted with a mains cable, this should be fitted by the installer. Cable
type (minimum size) H05VV-F 1.5mm² three core for peak and 2.5mm² three core for
o-peak for connection to the fixed wiring of the premises through suitable isolation
devices positioned adjacent to the heater. The supply circuits to the heater must
incorporate a double pole isolating switch having a contact separation of at least 3mm.
In installation the supply cord may be cut to the appropriate length for the electrical
connection point. Excess cable should not be inserted or stored behind the heater.
If, during reassembly of the heater, a part of the thermal insulation shows damage or
deterioration, it should be replaced by an identical part.
WARNING: All electrical connections to the terminal block must be secure to prevent
risk of ignition. Tighten to 0.5 Nm.
3
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex XLE070 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info