500147
15
Zoom out
Zoom in
Vorherige Seite
1/50
Nächste Seite
15
5 Maintenance
GB
5.4 Cleaning the hygienic exhaust filter
It is best to check/clean the hygienic exhaust filter each time you clean
the dual motor protection filter, Chapter 5.3, "Cleaning the dual motor
protection filter".
1. Switch off the appliance, Chapter 4.3, "Switching off".
2. Slide the release catch of the exhaust filter cover to the right (Fig. 13/A)
and open the exhaust filter cover.
3. Remove the hygienic exhaust filter (Fig. 13/B).
4. Tap the dirt out of the hygienic exhaust filter over a dustbin.
5. Remove residual dust with a soft brush, e.g. the supplied furniture
brush.
6. If the hygienic exhaust filter is still dirty after this procedure, thoroughly
rinse it by hand in running water until all dirt is gone.
7. If the exhaust filter is damaged, deformed or too soiled, replace it
(ordering information Chapter 5.5, "Spare parts and accessories").
8. Place the clean/new exhaust filter back into its receptacle (Fig. 14/A).
9. Fit the exhaust filter cover on the bottom first and then pivot it in
upwards into place (Fig. 14/B).
5.5 Spare parts and accessories
Ordering address: Page 48, "International Service"
Further information: www.dirtdevil.de
The adjacent accessory parts and spare parts can be reordered.
5.6 Before you send in the appliance
Before contacting your authorised Royal dealer, Royal service partner or
appliance market or sending in the appliance, first follow the procedure in
the following table to check if you can solve the problem yourself.
A
ATTENTION:
The filter is washable, but it may not be cleaned in dishwashers or
washing machines. Also, do not use detergents or brushes with hard
bristles to clean the filters. Let the filter dry for approx. 24 hours at room
temperature after washing it. Only put it back in place when it is
completely dry.
ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have purchased by reordering.
Item number Description
2838001 Dual motor protection filter consisting of:
1 foam plastic filter element and 1 filter holder
2838002 1 hygienic exhaust filter
M203-5 1 parquet brush
M209 1 turbo brush
M219 1 mini turbo brush
M232 1 long, flexible crevice nozzle
WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing Chapter 4.3, "Switching off".
NOTE:
If you were unable to solve the problem with the information in the above
table, contact Customer Service (Page 48, "International Service").
Problem Solution
The appliance
will not start.
The socket does not carry current.
Test the vacuum cleaner at another socket which you
are sure carries current.
Power cord is damaged. Have the cord replaced by the
Royal Appliance Customer Service, address Page
48, "International Service".
The vacuum
cleaner stops
suddenly.
The overheating protection has tripped (possibly due
to blocked suction channels, filters, or similar).
Switch the appliance off and pull the plug out of the
socket. Remove the cause of overheating (e.g. by dis-
assembling telescopic tube and suction hose and re-
moving the obstacle and/or cleaning filters). Wait for
about 45 minutes. After the appliance has cooled off,
you may switch it on again.
The cleaning re-
sults are unsat-
isfactory in spite
of the appliance
working correct-
ly.
The bypass vent (Fig. 1/26) is open.
Close the bypass vent (Fig. 1/26).
The attached nozzle is unsuitable.
Change the nozzle, Chapter 3.2, "Selecting the
proper nozzle".
The position of the "carpet/hard floor" selector (Fig. 1/
2) is unsuitable. Set the "carpet/hard floor" selector
(Fig. 1/2) to the correct position for the type of floor,
Chapter 4.2, "Vacuum cleaning", step 4.
The dust container is full.
Empty the dust container, Chapter 5.1, "Emptying
the dust container".
The filters are dirty. Clean the respective filter
Chapter 5.2, "Cleaning the dust container and cy-
clone unit" or Chapter 5.4, "Cleaning the hygienic ex-
haust filter".
When vacuum-
ing with the long,
flexible crevice
nozzle, there is
suddenly a high-
pitched whistling
and the suction
power drops
considerably.
The pressure in the vacuum cleaner became too low
and caused the safety valve to trigger.
Open the bypass vent until the valve no longer trig-
gers.
Problem Solution
M3230.book Seite 15 Dienstag, 5. Juni 2012 11:53 11
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dirt Devil M3230 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Dirt Devil M3230

Dirt Devil M3230 Bedienungsanleitung - Deutsch, Englisch, Französisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info