629513
5
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
Elite Control Operations Manual Important Programming Notes To Installer And End User
L-2230 ENGLISH 3
IMPORTANT PROGRAMMING NOTES TO INSTALLER AND END USER
1. If your air conditioning unit is Cool Only (if it does not have a reversing valve), then you MUST select Cool Only Mode.
DO NOT select Automatic Mode for a Cool Only unit. If Automatic Mode is selected and the thermostat calls for heat,
the compressor will run. Since there is no reversing valve, the air conditioning unit will supply cool air when heating is
desired. Cool Only units do not heat. See “Modes of Operation” on page 5 for more information on how to set the
proper operating mode.
2. If your air conditioning unit has a Shaded-Pole (SP) fan motor instead of a Split-Capacitor (SC) High-Velocity (HV) fan
motor, you MUST program “SP” into parameter P-14 before operating the equipment. The SP units are recognizable
by an overhanging blower motor. (The SC motor of an HV unit is inside the blower, and the unit has “VTD” or “HV” in
the model number.) Only reprogram this parameter if you do NOT have an HV blower.
NORMAL HEATING OR COOLING CYCLE
In Automatic Mode, heating and cooling are supplied as required. If cooling is required, the system will start a cooling cycle
when the cabin temperature exceeds the set point by 2°F (1.1°C) and will continue to cool until the temperature equals the set
point. (See “P-23: Set Point Temperature Differential” on page 10 for instructions on how to reduce this variation to 1°F
[0.55°C].) The cabin temperature must drop below the set point by at least 4°F (2.2°C) in order for the system to switch from
cooling to heating. Similarly, if heating is required, the system will start a heating cycle when the cabin temperature is below the
set point by 2°F (1.1°C) and will continue to heat until the temperature equals the set point. The cabin temperature must exceed
the set point by at least 4°F (2.2°C) in order for the system to switch from heating to cooling.
If you select Cool Mode, only cooling is supplied. If you select Heat Mode, only heating is supplied. The cabin temperature in
either mode is maintained within 2°F (1.1°C) of set point by default. (See “P-23: Set Point Temperature Differential” on page 10
for instructions on how to reduce this variation to 1°F [0.55°C].) When the heating or cooling set point is satisfied, the
compressor cycles off and the fan returns to low speed. The fan speed remains constant if Manual Fan Speed is selected.
For more information on this feature, see “Modes of Operation” on page 5.
REVERSING VALVE OPERATION
The position of the reversing valve determines if the system is in Cool Mode or Heat Mode.
In addition, the reversing valve is programmed to toggle in these situations:
When the system is running and heating or cooling is required, the reversing valve toggles to the opposite mode to
reduce the starting surge of the compressor.
When a cooling or heating cycle is called for and if the system has been off for less than 75 seconds.
When a cycle is interrupted from the display panel by pressing the Power button or changing the set point.
Unnecessary valve toggling is limited to reduce reversing valve noise. You can totally eliminate valve toggling by programming
the minimum compressor staging delay to 75 seconds or greater (see “P-3: Compressor Staging Time Delay” on page 8 for
more information).
Power-On Reset, which occurs when the system is powered up, always initiates a valve toggle.
INSTALLING THE DISPLAY PANEL
CHOOSING THE LOCATION
Before mounting the control panel, consider the location. The display panel’s built-in air sensor provides excellent room-air
temperature sensing when properly located and installed. For air sensor location see item 2 in Figure 1, page 2.
Mount the display panel on an inside wall, slightly higher than mid-height of the cabin, in a location with freely circulating air
where it can best sense average temperature. Its distance from the air conditioner must be within the 15’ (4.5m) length of the
display cable (custom lengths available).
Do not mount the display in direct sunlight, near any heat-producing appliances or in a bulkhead where temperatures radiating
from behind the panel may affect performance. Do not mount the display in the supply-air stream. Do not mount the display
above or below a supply-air or return-air grille. Do not mount the display behind a door, in a corner, under a stairwell or any
place where there is no freely circulating air.
If you can not mount the display in a suitable location for accurately sensing room temperature, install the optional remote air
sensor.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dometic Elite Control DX systems wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info