55
DO362A
www.domo-elektro.be
EN
possibly also the SLEEP setting.
TIMER
ON
time. Every press of this button will elevate the current time. The max.
Timer setting is 24 hours. For cancelling the auto on function you keep on
pressing the “timer on” button until “0.0” is displayed.
timers.
Make sure the unit is plugged in.
Press the “timer on”button. The display will show the last setting of the
“timer on” mode. Press the “ timer on” button again to start setting the
delay time you want to air conditioning to start working. Every time you
press the timer the delay time will change. Max. delay timer setting is 24
hours.
After setting the timer , it takes about 2 sec. Before the set temperature will be displayed again.
Illustrations to illustrate a 2.5-hour delayed start.
TIMER
OFF
Press this button if you want your air conditioning to shut down at a certain
Max timer setting is 24 hours. For cancelling the auto on function you keep
on pressing the “timer on” button until “0.0” is displayed.
timers.
delay time you want the air conditioning to stop working. Every time
you press the timer the delay time will change. Max to set delay time
is 24 hours. After setting the timer, it tak es about 2 sec. Before the set
temperature will be displayed again.
Illustrations to illustrate a 5-hour delayed stop.
Please note: this time is always from the hour when you programme the setting. For example: it is now 1
h.
9 9
10 10
NOTE:
" 0.0h "
When setting the TIMER ON or
TIMER OFF functions, up to 10 hours,
the time will increase in 30 minute
increments with each press. After 10
hours and up to 24, it will increase i n 1
hour increments. The timer will revert to
zero after 24 hours.
Y ou can turn off either function by
setting its timer to .
2. Press the TIMER ON button repeatedly
t o s e t the time when you want the unit to
turn on.
3. W ait 2 seconds, then the TIMER O N
function will be activated. The digital
display on your remote control will then
return to the temperature display.
2. Press the TIMER OFF button repeatedly
t o s e t the time when you want the unit to
turn off.
3. W ait 2 seconds, then the TIMER OFF
function will be activated. The digital
display on your remote control will then
return to the temperature display.
Example: Setting unit to turn on after 2.5
hours.
Example: Setting unit to turn off after 5
hours.
2 sec
ON/OFF
MODE
FAN
SHORT
CUT
TIMER ON
TIMER OF
F
TEMP
S
LE EP
1 sec
x5
1
3
2
4
TIMER OFF function
The TIMER OFF function allows you to
set a period of time after which the unit
will automatically turn off, such as when
you wake up.
1.
This number indicates the
amount of time after the current time
that you want the unit to turn on.
For example, if you set TIMER ON for
2 hours, will appear on the
screen, and the unit will turn on after
2 hours.
Press the TIMER ON button. By
default, the last time period that you
s e t a n d an "h" (indicating hours)will
appear on the display .
Note:
" 2. 0h "
1.
This number indicates the
amount of time after the current time
that you want the unit to turn off.
For example, if you set TIMER OFF for
2 hours, will appear on the
screen, and the unit will turn of f after
2 hours.
Press the TIMER OFF button. By
default, the last time period that you
s e t a n d an "h" (indicating hours)will
appear on the display .
Note:
" 2. 0h "
2 sec
x10
ON/OF F
MODE
F A N
SHOR T
CUT
TIMER ON
TIMER OF
F
TEMP
S
L EEP
1 sec
1
3
2
4
TIMER ON function
The TIMER ON function allows you to set
a period of time after which the unit will
automatically turn on, such as when you
come home from work.
Y our air conditioning unit has two
timer-related functions:
TIMER ON - sets the amount of timer after
which the unit will automatically turn on.
TIMER OFF - sets the amount of time after
which the unit will automatically turn off.
TIMER ON TIMER ON
TIM E R O F F TIM E R O F F
Continue to press
TIMER ON or
TIMER OFF until
desired time is
reached.
Setting the TIMER function
ON /OFF
T E M P
S H O R T
C U T
TIME R
O N
TIME R
O F F
M O D E
FA N
SLEE P L E D
T i m e r o n
F O L L O W
S W I N G
ION
M E
9 9
10 10
NOTE:
" 0.0h "
When setting the TIMER ON or
TIMER OFF functions, up to 10 hours,
the time will increase in 30 minute
increments with each press. After 10
hours and up to 24, it will increase i n 1
hour increments. The timer will revert to
zero after 24 hours.
Y ou can turn off either function by
setting its timer to .
2. Press the TIMER ON button repeatedly
t o s e t the time when you want the unit to
turn on.
3. W ait 2 seconds, then the TIMER O N
function will be activated. The digital
display on your remote control will then
return to the temperature display.
2. Press the TIMER OFF button repeatedly
t o s e t the time when you want the unit to
turn off.
3. W ait 2 seconds, then the TIMER OFF
function will be activated. The digital
display on your remote control will then
return to the temperature display.
Example: Setting unit to turn on after 2.5
hours.
Example: Setting unit to turn off after 5
hours.
2 sec
O N / O F F
M O D E
F A N
SHOR T
CUT
TIMER ON
TIMER OF
F
TEMP
S
L E EP
1 sec
x5
1
3
2
4
TIMER OFF function
The TIMER OFF function allows you to
set a period of time after which the unit
will automatically turn off, such as when
you wake up.
1.
This number indicates the
amount of time after the current time
that you want the unit to turn on.
For example, if you set TIMER ON for
2 hours, will appear on the
screen, and the unit will turn on after
2 hours.
Press the TIMER ON button. By
default, the last time period that you
s e t a n d an "h" (indicating hours)will
appear on the display .
Note:
" 2. 0h "
1.
This number indicates the
amount of time after the current time
that you want the unit to turn off.
For example, if you set TIMER OFF for
2 hours, will appear on the
screen, and the unit will turn of f after
2 hours.
Press the TIMER OFF button. By
default, the last time period that you
s e t a n d an "h" (indicating hours)will
appear on the display .
Note:
" 2. 0h "
2 sec
x10
ON/OFF
MODE
FAN
SHORT
CUT
TIMER ON
TIMER OF
F
TEMP
S
LEEP
1 sec
1
3
2
4
TIMER ON function
The TIMER ON function allows you to set
a period of time after which the unit will
automatically turn on, such as when you
come home from work.
Y our air conditioning unit has two
timer-related functions:
TIMER ON - sets the amount of timer after
which the unit will automatically turn on.
TIMER OFF - sets the amount of time after
which the unit will automatically turn off.
TIMER ON TIMER ON
TIMER O FF TIMER O FF
Continue to press
TIMER ON or
TIMER OFF until
desired time is
reached.
Setting the TIMER function
ON /OFF
T E M P
S H O R T
C U T
TIME R
O N
TIME R
O F F
M O D E
FA N
SLEE P L E D
T i m e r o n
F O L L O W
S W I N G
ION
M E