CONVERSION INSTRUCTIONS
The conversion must be carried out by a qualified fitter.
Before commencing the conversion:
1.Disconnect the gas supply.
Removing the burner unit
To be able to replace essential components,the entire
burner unit must be taken out of the heater.To do this:
- Open the front and the glass pane.
- Remove the vermiculite tray.
- Disconnect the gas supply.
- Take the burner unit out of the appliance.
Replacing the components
Pilot-light jet
Unscrew the nut (1) at the end of the pilot-light hose,pull
the hose with ring clamp our of the pilot-light burner and
remove the jet.Fit the new jet and tighten the nut on the
pilot-light hose firmly.
Main burner jet and airflow regulator
The main burner jet is located under the airflow regulator.
Remove the self-tapping screw on the left to take out the
burner tray.Remove the jet (3) with a spanner and fit the
new one.Replace the burner tray
and replace the airflow regulator.
For G30 (butane) don’t (re)place the airflow
regulator.
English
Alto/Basso
CONVERSION INSTRUCTIONS
23
A
B