INSTALLATION MANUAL
Follow the procedure described below:
Ø
Disconnect the pipes from the gas control (flexible gas pipe, aluminium pilot burner pipe and thermocouple 1);
!Caution
The red wire of thermocouple 2, if applicable, must remain connected to the gas control.
Ø
Disconnect the gas control from the burner mounting plate by unscrewing the self-tapping screw.
Ø
Carefully unwind the red and black wire of thermocouple 2, if applicable.
Ø
Carefully lay the gas control together with the wires of thermocouple 2, the ignition cable, the flexible gas hose,
the aluminium pilot burner pipe and the type plate plus chain in the direction of the control hatch.
!Caution
Prevent dirt in gas pipes and connections;
Avoid kinks in the pipes.
!Caution
Make sure the ignition cable cannot come into contact with other wires;
The data plate should remain attached to the chain.
Ø
Set the height of the appliance using the adjustable feet (if applicable).
Ø
Make the appliance level at the same time.
!Tip
The construction frame for most 2 or 3 sided appliances can be adjusted. This will allow you to connect the
construction frame to the chimney breast correctly. For 2 or 3 sided appliances that cannot be adjusted, we would
like to refer you to chapter 5.9 'Additional instructions'.
!Caution
do not ignite the appliance before the gas and discharge connections have been fully installed, first observe the
procedure described in chapter 7.3.
5.5Placingthechimneybreast (if applicable)
In order to provide proper heat discharge, there should be sufficient space around the appliance. The chimney
breast should be ventilated sufficiently by means of ventilation holes (incoming and outgoing).
!Caution
Use non combustible and heat-resistant material for the chimney breast, including the top of the chimney
breast, the material inside the chimney breast and the back wall of the chimney breast.
Make sure that the appliance is not carrying the weight of the chimney breast when using stone-like
materials.
The passage of the ventilation holes (outgoing), which are placed as high as possible, is stated in Appendix 2,
Table 2.
!Caution
When placing the chimney breast, you should take the following into account (see Appendix 3, fig. 2):
the location of the control hatch: this must be placed as low as possible;
the dimensions of the control hatch; see Placing the control hatch section 5.6;
the Dru control hatch is not supplied with all appliances. Nevertheless, we recommend only using a Dru
control hatch, if available, exept in the case of B 11 AS/BS appliances. If you decide not to take this option, you
will have to make a 100 cm2 ventilation hole that is placed as low as possible, for the benefit of the incoming
ventilation;
the location of the ventilation holes (V) (outgoing);
maintain a minimum 30 cm distance between the top of the ventilation hole (outgoing) and the ceiling of the
house.
the measurements of the glass pane, so that it can be placed/removed after placing the chimney breast;
the protection of the gas control and the pipes against cement and plaster.
If possible, you should place decorative strips, frames, etc., after any required structural work has been
completed. Avoid the use of painter's tape. If this is not possible: please use good quality painter's tape and
remove it immediately after plastering or painting work has been completed.
!Tip
You should preferably apply the ventilation holes (outgoing) on both sides of the chimney breast. You can use
DRU ventilation elements.
Prior to completely closing the chimney breast, check whether the discharge / concentric system is placed
correctly.
whether the channels, fixing brackets and possible clip bindings, which cannot be reached after installation,
are fastened by means of self-tapping screws.
7
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DRU Diablo Next wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von DRU Diablo Next

DRU Diablo Next Installationsanweisung - Deutsch - 36 seiten

DRU Diablo Next Bedienungsanleitung - Deutsch - 20 seiten

DRU Diablo Next Bedienungsanleitung - Englisch - 20 seiten

DRU Diablo Next Installationsanweisung - Holländisch - 36 seiten

DRU Diablo Next Bedienungsanleitung - Holländisch - 20 seiten

DRU Diablo Next Bedienungsanleitung - Holländisch - 16 seiten

DRU Diablo Next Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info