INSTALLATION MANUAL
6.3 Gas connection
Place a gas tap in the gas connection, close to the appliance.
- Make sure there is no dirt in gas pipes and
connections;
- Prevent twisting the gas tap when con-
necting the gas pipe.
The following requirements apply to the gas connection:
- use a gas pipe with the correct dimensions, so that no
pressure loss can occur;
- the gas tap should have the CE marking;
- you should always be able to reach the gas tap.
6.4 Placing the appliance
- Make sure that combustible objects and/
or materials have a distance from the ap-
pliance of at least 500 mm;
- Always place the appliance against a wall of
non combustible and heat-resistant
material;
- Take suffi cient measures to prevent tempe-
ratures of a wall behind the chimney breast
becoming too high, including the materials
and/or objects behind the wall;
- Do not make any changes to the appliance.
!Caution - Take the adjustable height of the appliance
into account; it depends on the setting of
the adjustable feet (see fi g. 1a and fi g. 1b);
- Take the minimum construction depth of
the appliance into account; Global 70/Glo-
bal 70 XT: 362 mm (see fi g. 2a and fi g. 2b);
- If required, install the Max vent system
prior to placing the appliance; see the
manual for the Max vent system;
- Take the different construction measure-
ments into account when applying the Max
vent system; see the manual for the Max
vent system.
!Tip You can determine the construction height
of the appliance (X in fi g. 2a and fi g. 2b)
yourself.
Place the appliance as follows:
Determine the location of the appliance.
Determine the construction height of the appliance.
Provide a gas connection at the location. For details,
see section 6.3.
Make a passage for the fl ue gas discharge/combustion air
supply system with the following diameters. For details,
see section 6.5.
- Ø160 mm for a wall terminal through non combustible
material;
- Ø 250 mm for a wall terminal through combustible
material;
- Ø160 mm for a roof terminal through non combustible
material;
- Ø 250 mm for a roof terminal through combustible mate-
rial.
Place the appliance on its destined location.
The gas control is mounted under the appliance, at the bur-
ner plate. It should be disconnected and placed in the control
box at a later stage. The control box is not part of the appli-
ance's standard equipment and is available at your dealer. For
placing the gas control in the control box, see section 6.7.
Follow the procedure described below:
Disconnect the pipes from the gas control (fl exible gas
pipe, aluminium pilot-fl ame pipe and thermocouple 1).
!Caution The red wire of thermocouple 2 must
remain connected to the gas control.
Disconnect the gas control from the burner plate by
unscrewing the self-tapping screw.
Carefully unwind the red and black wires of
thermocouple 2.
Lay the gas control together with the wires of
thermocouple 2 in the direction of the control box.
- Make sure there is no dirt in gas pipes and
connections;
- Avoid kinks in the pipes.
Roll out the pipes in the direction of the control box.
Roll out the ignition cable in the direction of the control
box.
!Caution - Make sure the ignition cable cannot come
into contact with other wires;
- The data plate should remain connected to
the chain.
Place the chain with the data plate in the direction of the
control box.
Set the height of the appliance using the adjustable feet and
Make the appliance level at the same time.
- Do not place the appliance too tightly
against the back wall; this is guaranteed by
means of the spacer brackets;
- Make sure the space between the adjusta-
ble feet is kept free;
- Do not cover the appliance and/or do
not wrap it in an insulation blanket or any
other material.
6.5 Flue gas discharge / combustion air supply
system
6.5.1 General
The appliance is of the C11/C31 type.
The appliance is connected to a combined fl ue gas
Caution
Caution
Caution
Caution
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DRU GLOBAL 70 XT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von DRU GLOBAL 70 XT

DRU GLOBAL 70 XT Bedienungsanleitung - Deutsch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Englisch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Holländisch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info