CLASSIC-machines
Additional instructions: Machines with integrated motor - version 00.0 - dated 10/2012 6
. Sewing light connection
The PCB plug connector for the for the sewing light cable is
situated on an extra PCB on the left side behind the valve cap.
Fig. 5: Connecting the sewing light cable
Connecting the sewing light cable:
• Cable of the integrated sewing light: Plug connector on the
top (2)
• Cable of the single-diode sewing light: Plug connector in the
center (3)
Use the adapter 9870 867022.
Risk of death due to electric shock
The sewing light control is directly connected to the
mains supply and is live even when the main switch
is switched off.
Therefore it is essential to pull out the mains plug,
before you connect the sewing light.
Make sure that the mains plug cannot be plugged in
again by mistake.
DANGER
1
2
3
(1) - Sewing light cable
(2) - Plug connection for the cable of the integrated sewing light
(3) - Plug connection for the cable of the single-diode light