Where to look for blockages
Check that tools are clear of
blockages.
Remove bin assembly from
machine.
Remove wand and check
inside for blockages.
Press hose release button A
from front of machine and
slide hose out with lower
cable winder from rear.
Check inside hose for
blockages.
Important
Please note that clearing
blockages is not covered by
your cleaner’s guarantee.
Turn power off and unplug
before starting to clear any
blockages.
NB Should any part of the
machine become blocked
it may overheat and stop
due to the thermal cut-out
being triggered. Unplug
from mains and leave to
cool down for at least
30 minutes.
A
Tilt machine forward and
slide out U-bend airway
inspection B. Check inside
for blockages.
Squeeze valve release
catches to remove airway
inspection valve C. Check
inside for blockages.
Lie cleaner on its front.
1 Undo coloured fasteners
using a coin and remove
soleplate.
2 Clear the brushbar
obstruction, carefully
cutting away any
threads.
Replace soleplate and tighten
fasteners.