5.2 Sensor-2 monitoring
5.2.1 Sensor-2 as alarm contact
Alarm function for sensor-2 in armed mode can be selected as following:
Example: Sensor 2 is a normally closed contact that should trigger an un-delayed silent alarm on position I/II
1. Slide function switch to PROG
2. Enter sequence *. 9. 3. 1. 7 5 7 #. #.. .
Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing *..
4. Enter sequence 0. 0. 0. 0 0 1. 1. 1. .
R-Siren Entry-Delay Connect. mode Sensor on.. Type
0: off 0:off 0: Listening-in I / II / III 00: inactive
1: on 1:on 1: Hands-free 0 0 1 01: Normally open contact
0: enabled 10: Emergency-contact according to section 5.2.2
1: disabled 11: Normally closed contact
5. Press key #. .
The new register (bit 7 -> bit 0) will be announced
6. Slide function switch to OFF
5.2.2 Sensor-2 as emergency-sensor
If sensor-2 is enabled in section 5.2.1 as emergency-contact an emergency-call is triggered if the contact is in alarm
position for at least one second. An emergency call does not depend on the position of the selection switch and is also
active if the system is disarmed
5.2.2.1 Emergency call
1. Slide function switch to PROG
2. Enter sequence *. 9. 3. 1. 7 6 0 #. #.. .
Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing *..
4. Enter sequence 0. 1. 1. 0 0 0. 1. 1. .
R-Siren Entry-Delay Connect. mode Sensor on.. Type
0: off 0:off 0: Listening-in I / II / III 00: inactive
1: on 1:on 1: Hands-free 0 0 0 01: Normally open contact
0: enabled 10: Plug&Protect (auto-detected at power up)
input-2 is open => Normally open monitoring
input-2 is closed => Normally closed monitoring
11: Normally closed contact
5. Press key # .
The new register (bit 7 -> bit 0) will be announced
6. Slide function switch to OFF
5.2.3 Sensor-2 as entry-detector (Gong function)
A sensor-2 activity can also be signalled locally (Gong-function) according to the following procedure:
Example: Sensor-2 shall announce an incoming person with a loud beep on position II.
1. Shift function switch to PROG
2. Enter sequence *. 9. 3. 1. 7 3 2 #. #...
Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing *..
4. Enter sequence 0. 0. 0. 1 0 1. 1. 1. .
Unused Gong on.. Gong-type
000: I / II / III 00: Gong
1 0 1 01: --
0: enabled 10: Individual message
1: disabled 11: Beep loud
5. Press key #.
The new register (bit 7 -> bit 0) will be announced
6. Shift function switch to OFF
Fact
ory default for gong
-
function sensor
-
1
000 111 00
Note:
If you do not want to
trigger an alarm on
position II you have to
disable alarm according to
section 5.2.1
Factory default for sensor
-
2 monitoring
00 0 000 00, => inactive
Factory default for emergency
-
call by sensor
-
2
0 1 1 000 11: => delayed alarm in hands-free mode.
Contact type: NC
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EasyAlarm BASIC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von EasyAlarm BASIC

EasyAlarm BASIC Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info