515345
28
Zoom out
Zoom in
Vorherige Seite
1/32
Nächste Seite
28
11. ACCESSORIES
Further accessories can be found on our homepage on www.easyalarm.ch.
11.1Motion / Presence detector-PIR-RJ45 (Plug&Protect)
11.1.1 Preliminary considerations
Choose the mounting location after careful consideration of the area to be protected.
The motion detector should be located so that an intruder will cross the infrared beam
pattern. If used to verify presence, a regular used room should be detected. Figure
shows the different infrared beam patterns at a typical mounting height of 2.5m.
Notes:
Do not mount detector towards direct sunlight or near to heat sources.
Do not mount detector behind items like glass or curtains because the infrared-
beam cannot penetrate them.
Keep away pets like cats or dogs from the protected area.
Do not protect the same area by more then one detector, because they can interfere.
11.1.2 Installation
Connect the cable of the motion detector on the EXT port of the alarm unit. The AC adapter of the alarm unit provides the
power supply of the detector
11.1.3 Activation
Provided the motion detector is plugged in, EasyAlar detects the motion detector during the switching on procedure.
Important notes:
By disconnecting the motion detector during the operation mode, an alarm is
triggered followed by the announcement: ”alarm due to sensor 1, sensor
failure!”
By connecting the motion detector after the start up procedure of the alarm unit,
an alarm is triggered followed by the announcement: “alarm due to sensor 1,
sensor 1 activated!
11.1.4 Deactivation
If the motion detector is not plugged in, EasyAlarm® automatically deactivates the
supervision of the motion detector.
11.1.5 Specification
Supply voltage 9..16 VDC (through AC-adapter)
Dimension 107 x 58 x 39 mm (L x W x D) without swivel
Weight 75 g
Cable length 8m (RJ45)
Detection type passive infrared (PIR)
Alarm contact normally closed
11.1.6 Adjustment
Safety note:
Before you open cover please check, that the telephone cord is DISONNECTED.
Otherwise you can get in contact with the telecommunication voltage!
Remove the front cover by twisting a flat screwdriver in the slot between the cover and
the base at the bottom of the motion detector
11.1.6.1 Pulse count
You can set PULSE jumper at position 1,2 or 3 corresponding to the desired pulse count before an alarm will be triggered.
Default = 2.
11.1.6.2 WALK-test
To disable LED indication, remove the LED jumper and place it on one pin only. To activate LED indication, place LED
jumper over both pins.
11.1.6.2.1 Mounting height
If motion detector is not mounted at 2.5m you can adjust like this:
5. Loosen the PC-Board holding screw. Slide the PC-Board so that the plastic
pointer on the right side is positioned at the appropriate scale position.
For higher than 2.5m => Slide PC-Board up
For lower than 2.5m => Slide PC-Board down
6. Tighten the PC-Board holding screw
7. Mount front cover
8. Walk through the entire protected area and observe the LED to ensure full
coverage
Mounting screw
28

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EasyAlarm CONTROL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von EasyAlarm CONTROL

EasyAlarm CONTROL Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info