536309
2
Zoom out
Zoom in
Vorherige Seite
1/4
Nächste Seite
3. Installation
The controller should be installed at a place in the
room which:
is freely accessible for ease of operation
is free from curtains, cupboards, shelves etc.
permits free air circulation
is not directly exposed to solar radiation
is free from draughts (opening of windows and
doors)
is not directly exposed to heat source
is not located on an external wall
is 1,5 m above the floor.
Install direct on a conduit box, or with adapter frame
ARA 2E.
4. Electrical connection
Caution: disconnect electric circuit from supply
In making the electrical connection, proceed in the
following sequence:
Remove the temperature adjustment knob (1)
Push the mounting hook outwards, using a screw
driver
Remove housing top
Push out battery compartment, using a screw dri-
ver, remove battery protection strip
Carry out electrical connection in accordance
with circuit diagram (see housing top)
Note:
Connect n/c valves to terminal 2
Connect n/o valves to terminal 3
When temperature is below set value, contact
9-2 is closed.
When mode selector switch is in Off position
n/o and n/c valves are closed.
5. Technical data
Order no. easy 2t daily timer
easy 2w weekly timer
EDP no. easy 2t 515 2701…
easy 2w 515 2702…
Supply voltage Battery 1,5 V type LR 14
Alkaline
Battery life time approx. 2 years
Temperature setting range:
Room temperature 530°C
Set back temp. 530°C
Frost protection approx. 5 °C (fixed)
Mode of control on-off
Static hysteresis approx. 0,2 K
Output Relay, 1 x c/o contact
Switching current 10 mA…10 A cos ϕ= 1
max. 4 A cos ϕ= 0,6
max. 10 terminal
actuators
Switching voltage 12…250 V AC
Switches day / automatic / night /
frost protection / off
Temperature sensor integrated
Range limitation integrated in the
setting knob
Timer:
Accuracy < 10 min/year
Switching time setting every 15 min daily timer
every 1 h weekly timer
Degree of protection IP 30
Protection class II (see important!)
Operating temperature –1040°C, without
moisture condensation
Storage temperature –2570°C
Dimensions 160 x 80 x 36 mm
Weight (with battery) approx. 270 g
Mounting and
Operating Instruction for
2-wire-clock-
thermostat easy 2
Important!
The electronic clock thermostat must not be
opened except by authorized personel. Any
installation must be in accordance with the
circuit diagram provided inside the cover, and
must follow these instructions.
The current safety regulations must be observed.
For protection class II recognition, adequate
installation measures must be taken.
This electronic clock thermostat, which can be
installed separately, is designed exclusively for
temperature control in dry and closed rooms
and standard environments. It has radio interfe-
rence suppression in accordance with VDE
0875 T.14 and EN 55014 respectively and
operates in accordance with 1C (EN 60730).
1. Applications
The electronic timer thermostat easy 2 can be used
for controlling the room temperature in connection
with:
Warm water convector or underfloor heating
Electric convector, ceiling and storage heating
Night storage heating
Chillers
Circulating pumps
Burners
Heat pumps etc.
Features
Very simple operation
Day and night temperatures independently selec-
table
5 operating modes for:
Permanent comfort temperature
Permanent set back temperature
Timer mode (automatic)
Frost protection
Off
Available with daily- or weekly- timer
Hinged cover
control algorithm On-off
Relay output, 1 changeover contact
New EBERLE design 2000
2. Function description
The timer thermostat is designed to control the
room temperature.
In the automatic mode, a changeover is effected
between comfort and set-back temperature by the
built in timer.
If room temperature falls below set value, heating is
started.
6. Operation
Setting of temperatures
Comfort temperature (day temperature)
This is set by means of the adjustment knob (1)
on the outside.
Setback temperature (night temperature)
This is set by means of the adjustment knob (2)
under the cover.
Setting the time
Place one finger on the dial (3) and turn it in the
desired direction to set the time.
Arrow (4) points at the selected time.
Setting the switching times
Using a pointed object, move the switch actua-
tors (5) into desired position.
Outward = Comfort temperature
Inward = Set-back temperature
Mode selector switch (6)
É Comfort temperature, permanent (day temp.)
2 Automatic mode, timer-controlled changeover
between comfort- and set back temperature
Set-back temperature, permanent (night temp.)
P Frost protection, permanent (5°C)
Off, no control taking place. The controller itself
is not separated from operating voltage.
Battery change
If the timer noticeably lags, battery should be
changed within 1 week.
When changing the battery, observe correct po la-
rity.
Wiring diagram
12
3
4 5 6
Ñ
6
9
2
3
5
4
3
2
1
468 931 032 740-2
Battery handling
Batteries, rechargeable or not, should
not to be disposed of into ordinary
household waste. Instead, they must
be recycled properly to protect the
environment and cut down the waste
of precious resources. Your local waste manage-
ment authority can supply details concerning the
proper disposal of batteries.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EBERLE Easy 2T wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info