PLEASE NOTE: 45H IS FOR OUTDOOR PERMANENT INSTALLATIONS ONLY AND 45HI IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL
AND ALL ECCOTEMP CONTECT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
English
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
• To supply hot water to upper oors,
additional water pressure (0.44 psi/ft)
must be ensured.The measurement should
be calculated by the distance between the
water inlet of the water heater (ground
level) to the hot water faucet (upper oor level).
• Well water systems should be set at a
range of 50-60 psi.
• When the water is supplied from a water
supply tank, the height of the tank and the
diameter of the pipes and their relation to
water pressure, should be taken into
consideration. Gravity water pressure is
not recommended.
NOTICE: If the water ow resistance of a shower
head is too high, the burner in the water heater
will fail to ignite. Keep the shower head clean from
debris that could cause additional pressure drop.
NOTICE: If using mixing valves on the outlet,
choose one which prevents cold water pressure
from overcoming hot water line pressure.
IMPORTANT: Do not apply heat to the HOT or
COLD water connections. Any heat applied to the
water supply ttings will permanently damage the
internal components of the water heater.
Water Supply Connections
Plumbing should be carried out by a qualied
plumber in accordance with local codes.
Use approved plumbing materials and tools only.
To conserve energy and to prevent freezing,
insulate both cold and hot water supply lines. DO
NOT cover the drain valves.
To ensure proper operation of the water heater,
the following water pressure guidelines should be
followed:
• Operation of the water heater requires the
minimum water pressure of 14 psi and a
minimum water ow rate of 0.75 gpm.
• Additional water pressure is required for
long pipe runs and outlet tting(s) water
pressure drops.
• To maintain proper performance, ensure
sucient water supply pressure. The
Required Water Pressure = Min. Operating
Water Pressure (14 psi) + Pipe Pressure
Loss + Faucet and Shower Pressure Loss +
Safety Margin (more than 5 psi).
Mounting the 45-H Water Heater
Make sure the location of the water heater allows for easy access
and operation. The water heater should be located in an area where leakage of the
tank or connections will not result in damage to the area adjacent to the water heater
or to lower oors of the structure. When such locations cannot be avoided, it is
recommended that a suitable drain pan, adequately drained, be installed under the
appliance. The pan must not restrict combustion air ow.
In case of dry wall or concrete wall use dry wall anchors or lag bolts.
The water heater requires 120VAC/ 60Hz. Have a receptacle with
ground terminal near the water heater. The length of the power
supply cord is 5 feet.
Drill the holes as per the sizes in the gure to the left, put 2 expansion screws into the
top holes, and 2 rubber screws into the bottom holes.
Hang up the water heater unit, tighten the expansion screws, and put 2 wood thread
screws into the bottom holes.
When being installed directly on carpeting, the water heater shall be installed on a
metal or wood panel extending beyond the full width and depth of the water heater
by at least 3 in (76.2 mm) in any direction or, if the water heater is installed in an
alcove or closet, the entire oor shall be covered by the panel. The panel must be
strong enough to carry the weight of the heater when full of water.
CAUTION: Reinforcement of the wall is required in case the wall is not strong enough to hold the water heater.
CAUTION: This water heater must only be used with the following water supply system conditions:
• With clean, potable water free of corrosive chemicals, sand, dirt, or other contaminates.
• With inlet water temperatures above 32°F, but not exceeding 120°F.
• Free of lime and scale deposits.
• DO NOT reverse the hot and cold water connections. The water heater will not operate.
45-H
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eccotemp 45HI-NG wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info