782664
6
Zoom out
Zoom in
Vorherige Seite
1/22
Nächste Seite
ENGLISH
6
C US
Support: Support.Eccotemp.com Shop Online: Eccotemp.com Store Locator: Eccotemp.com/locator
PLEASE NOTE: THIS MODEL IS NOT RECOMMENDED, NOR HAS IT BEEN TESTED FOR ANY PERMANENT OR INDOOR INSTALLATION. THIS
MODEL IS PART OF OUR PORTABLE, OUTDOOR SERIES AND NEEDS TO BE TAKEN DOWN AND STORED IN A WARM, DRY PLACE AFTER EVERY
USE. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. VISIT SUPPORT.ECCOTEMP.COM FOR THE
LATEST VERSION OF THE MANUAL AND WARRANTY.
SAFETY
Drain
Pipe
WARNING: Never use an open ame to test for gas leaks, as property damage, personal
injury, or death could result.
The tankless water heater and its gas connections must be leak tested at normal operating
pressures before it is placed in operation.
Turn on the gas to the tankless water heater from the recommended gas cylinder.
Use a commercial leak detector or soapy water solution to test for leaks at all connections
and ttings.
Bubbles indicate a gas leak that must be corrected.
The factory connections should also be leak tested after the tankless water heater is placed in
operation cause water damage which may or may not be reparable. Please check the warranty
information found on our website at www.eccotemp.com for more information on freezing issues.
Leak Testing
Pressure Relief Valve
A new pressure relief valve, complying with the standard for pressure relief valves and automatic
gas shut-o Devices for Hot Water Supply Systems, ANSI Z21.22, must be installed at the hot water
outlet connection of the tankless water heater at the time of installation. Local codes shall govern the
installation of pressure relief valves.
The diagram below illustrates a pressure only relief valve. If local codes require a combination
and pressure relief valve be installed, an extension piece may be required.
For safe operation of the water heater, be sure that:
The pressure rating of the pressure relief valve must not
exceed 150 psi, the maximum working pressure of the
tankless water heater as marked on the rating plate.
The BTUH rating of the pressure relief valve must equal
or exceed the BTUH input of the tankless water heater as
marked on its rating plate.
No valve of any type should be installed between the
pressure relief valve and the water heater.
The discharge line must be NO SMALLER than the
outlet of the valve and must pitch downward to allow
complete drainage (by gravity) of the pressure relief
valve and discharge line.
The end of the discharge line should not be threaded or
concealed. No valve of any type, restriction or reducer
coupling should be installed in discharge line.
This water heater is for OUTDOOR installation ONLY. It must
NOT be installed indoors or in a conned space.
An air supply containing halogenated hydrocarbons may
be safe to breathe, but when it passes through a gas ame
corrosive elements are released that will shorten the life of
any gas burning appliance.
Propellants from common spray cans or gas leaks from
A/C and refrigeration equipment are highly corrosive after
passing through a ame and therefore should never be
used around the water heater.
The tankless water heater warranty is voided when failure of
the heater is due to operation in a corrosive atmosphere.
Combustion and Ventilation Air
Warning!
Gasoline, as well as other ammable
materials and liquids (adhesives, solvents,
paint thinners etc.), and the vapors
they produce are extremely dangerous.
DO NOT handle, use or store gasoline
or other ammable or combustible
materials anywhere near or in the vicinity
of a water heater or any other appliance.
Be sure to read and follow the labels on
the water heater, as well as the warnings
printed in this manual. Failure to do so
can result in property damage, bodily
injury or death.
T-Shap
e
Connector
Shower Hos
e
Pressure Relief Valv
e
Drai
n
Pipe
Pressure
Relief Valv
e
Drain Pipe
Shower Hos
e
Drain
Pipe Pressure
Relief Valve
Pressure
Relief Valve
Shower
Hose
Shower
Hose
T Shape
Connector
Gas
Supply
Drain
Pipe
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eccotemp EL5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Eccotemp EL5

Eccotemp EL5 Bedienungsanleitung - Französisch, Spanisch - 64 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info