PLEASE NOTE: FVI12 IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
English
To conserve energy and to prevent freezing, insulate both cold
and hot water supply lines. DO NOT cover the drain valves.
Install a shuto valve near the inlet of the water heater for service
and draining purposes. Before connecting the water supply pipe to
the water heater, open the shuto valve ·and clean out sand, debris,
air, caulking material, etc. inside the pipe. Connect to the water
inlet, then check water pressure. Close the shuto valve and clean the
water lter.
If a water heater is installed in a closed water supply system, such as
one having a back ow preventer in the cold-water supply line, means
shall be provided to control thermal expansion. Contact the water
supplier or local plumbing inspector on how to control this situation.
CAUTION: This water heater must only be used with the following water supply system conditions:
• With clean, potable water free of corrosive chemicals, sand, dirt, or other contaminates.
• With inlet water temperatures above 32°F, but not to exceed 120°F.
• Free of lime and scale deposits.
DO NOT reverse the hot and cold water connections. The water heater will not operate.
To ensure proper operation of the water heater, the following water pressure guidelines should
be followed:
Operation of the water heater requires the minimum water pressure of 20 psi to activate and a
minimum of 22 psi or greater to maintain activation.
Additional water pressure is required for long pipe runs and outlet tting(s) water pressure drops.
To maintain proper performance, ensure su cient water supply pressure. The Required Water
Pressure = Min. Operating Water Pressure (22 psi) + Pipe Pressure Loss + Faucet and Shower
Pressure Loss + Safety Margin (more than 5 psi).
To supply hot water to upper oors, additional water pressure (0.44 psi/ft) must be ensured. The
measurement should be calculated by the distance between the water inlet of the water heater
(ground level) to the hot water faucet (upper oor level).
Well water systems should be set at a range of 50-60 psi.
When the water is supplied from a water supply tank, the height of the tank and the diameter of
the pipes and their relation to water pressure, should be taken into consideration. Gravity water
pressure is not recommended.
IMPORTANT: Do not apply heat to the HOT or COLD water connections. Any heat applied to the
water supply ttings will permanently damage the internal components of the water heater.
NOTICE: If the water pressure resistance of a shower head is too high, the burner in the water heater
will fail to ignite. Keep the shower head clean from debris that could cause additional pressure drop.
Notice: If using mixing valves on the outlet, choose one which prevents cold water pressure from
overcoming hot water line pressure.
DO NOT use pipes with smaller diameters than the water supply connection of the water heater.
Be sure to connect the water inlet and the hot water outlet as shown on the water heater. If reversed,
the water heater will not function.
Installation of unions or exible copper connections are recommended on the HOT and COLD water
lines, so that the water heater may disconnect easily for servicing if necessary.
Plumbing should be carried out by a quali ed plumber in accordance with local codes. Use approved
plumbing materials and tools only.
Install a Check Valve between the water heater and the water shuto valve (See illustration below).
Water Connections
Installation
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eccotemp FVI-12 series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info