OPERATION INSTRUCTIONS
1. Turn on the circuit breaker to bring electrical power to the unit.
2. Open water faucet for a few minutes until water ow is continuous and all air is purged from water pipes. The
unit must be operated after the breakers are turned on.
3. After the unit is supplied with power, a beep sound can be heard and LED lights for 2 seconds, no other
display, the appliance keeps standby.
4. Touch to turn ON/OFF the water heater. When the unit is ON, LED displays actual water temperature
of the outlet. When the water heater is not operating, the screen will switch to the screen saver after 15
seconds. The display screen light will be off. Touch the screen, it will return to operating mode.
Touch and to adjust the outlet temperature. Temperature setting range is 86-127°F.
If the unit has been paused, You may initially get a short burst of very hot water while you turn on again.
Please run the water through for a few seconds to let the temperature settle down. Please check hot
water with hand before using hot water.
If the unit will not be used in winter, drain out water completely so that the heater will not FREEZE.
Please periodically clean inlet strainer and the shower to keep a free water ow.
5. Touch and hold on for 5 seconds to lock the operation keys and the will light in the display screen.
All the operational keys can not function.
Touch key and hold on for 5 seconds to lift the temperature lock and the will disappear in the display
screen. The operational keys can function right now.
6. The real time water ow (GPM) displays in the screen when there is water ow through the water heater.
7. There is a automatic memory function to avoid repetitive operation, while you turn on the appliance, the
default set temperature will be the same as last time it was set.
4.
TROUBLE-SHOOTING
Problems Possible Causes Corrective Actions
1. Inlet and outlet ttings leaking A. Fittings are not tight
B. Rubber washer worn-out
A. Tighten ttings.
B. Change rubber washer.
2. No LED signal A. Power not connected.
B. LED damaged.
A. Connect power to the unit.
B. Change LED.
3. Functional keys not working A. No water out from shower.
B. Water pressure too low.
C. Key or PCB damaged.
A. Open valve to get water.
B. Open valve to get pressure.
C. Change key or PCB.
4. Water too hot A. Too high temperature set.
B. Water ow too little.
A. Set a lower temperature.
B. Open valve more.
5. Water too cold A. Low temperature set.
B. Water ow too much.
A. Set a higher temperature.
B. Reduce water ow.
6. Reduced outlet water pressure Inlet strainer or shower clogged. Clean strainer and shower.
7. LED displays E1 Outlet temperature is over 67°F/153°F A, Reduce the temperature
B, Turn up the water ow
8. LED displays E3 Temperature sensor failure Please contact with your local dealer
9. Display overload Inlet water ow is too high. Reduce the inlet water ow
7 and 8 should only be performed by qualified electrician. The person who initially installed the unit is the best one to contact for help.
Error Code Error Description Possible Cause What to Do
E1 Overheating Thermal
Cut-off
The unit has reached a tempe-
rature of 153F/67C
Check the reset buttons on heating elements. Possible
Triac failure. Contact Technical Support for help.
E3 Sensor Malfunction The temperature sensor has
stopped working
Outlet Temperature sensor failure. Contact Technical
Support.
E4 Dry-heating thermal
cut-off.
In case of dry heating, the
unit’s electricity will be cut off
Possible Flow Meter sensor failure. Contact Technical
Support.
A03 Sensor Malfunction or
Power Board Failure
Power Board failure Possible Power Board Failure. Contact Technical
Support.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eccotemp iE series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info