Heating
This enables the HEATING mode and adjusts the heating cut-off temperature. The
HEATING mode is never activated for temperatures over the cut-off setpoint.
The icon indicates that there is a time schedule activated in the HEATING mode.
Heating buffer
This displays the setpoint temperature of the buffer storage tank and allows
adjustments to be made to the start-up temperature differential.
Heating units
This can be used to adjust the heating target outlet temperatures programmed by the
technical service. Each ramp increases or decreases the outlet temperature by 2ºC.
Interior terminals
Used to show and adjust the inside environment temperature setpoint (Tcons) and the
comfort temperature differential (DTc) of the terminals of each outlet unit.
Note: This configuration is associated with the heating and cooling services. If it is modified
for the heating service, it will automatically change for the cooling service and vice versa.
AUTO terminal control
Used to enable the automatic control of indoor terminals by bus (TH-Tune / THt).
Used to set the minimum (Tmin) and maximum (Tmax) indoor ambient temperature
values, between which the indoor terminals setpoints will pivot in the different
operating modes.
Note: When this option is activated, the indoor terminals perform automatic setpoint
changes depending on whether or not any of the energy efficiency functions are activated.
When the electrical surplus management or forced consumption functions (SG4) are
activated, the terminals automatically change to the most demanding room temperature
setpoint in accordance with the operating mode (Tmax for heating / Tmin for cooling).
When neither of these functions is activated, the indoor terminals change automatically to
the least demanding setpoint. Once the setpoint has been changed automatically, it can be
modified by directly adjusting each of the indoor terminals. The new setpoint will remain
in effect until such time as the conditions for a new automatic setpoint change are met.
Note: This configuration is associated with the heating and cooling services. If it is modified
for the heating service, it will automatically change for the cooling service and vice versa.