ENGLISH
POSSIBLE TROUBLESHOOTING
6) Signalling: smoke °C/high.
Problem: turns off due to exceeding maximum smoke temperature.
Actions: Check the pellet type
Check for anomalies with the smoke-extraction motor
Check to see if there are any obstructions in the smoke channel
Check correct installation
Gear motor faulty (CAT)
7) Signalling: Check button (signals an anomaly on the emergency button)
Actions: check maintenance status of the button and its board connection cable (DEALER).
8) Signalling: “Battery check”
Problem: The insert does not stop but the error appears on the display.
Actions: The buffer battery of the control board needs changing (DEALER).
Remember that this component is subject to regular wear and so it is not covered by the guarantee.
9) Signalling: ALARM - HIGH CURRENT: Activated when anomaNEAs, excessive current absorption is detected on the
gear motor.
Actions: Check functioning (CAT): gear motor - Electrical connections and electronic board.
10) Signalling: ALARM - LOW CURRENT: Activated when anomaNEAs, insuf¿ cient current absorption is detected on
the gear motor.
Actions: - Check functioning (CAT): gear motor - pressure switch - tank thermostat - electrical connections and elec-
tronic board
- Make sure that the two pellet hopper loading doors are tightly closed
11) Problem: Remote control not working
Actions: Move closer to the stove
check the battery and if necessary, replace it.
Synchronisation with automatic search on activation: when you put the batteries into the radio control a
radio channel search phase will start up automatically, and it will subsequently connect to the product de-
tected. So that this occurs correctly, make sure to switch the product on before inserting the batteries in the
radio control, and stay in the vicinity of the antenna in order to achieve radio coverage with certainty.
Synchronisation with automatic search and manual activation - it is possible to launch an automatic search
for a product manually, simply carry out the following operations after having already put the batteries into
the radio control:
- Go close to the product’s antenna and make sure it is connected to the electricity supply.
- With the display switched off (standby) hold the 0/I key down for 10”.
- After 10” a “NETWORK SEARCH” message appears on the display, then release the o/I key, as this means
that the automatic search has been activated.
- Automatic tuning of the radio channel will occur within a few seconds.
12) Problem: During ignition, the differential switch trips (DEALER):
Actions: • Check the condition of the ignition coil, the electrical system, and the electrical components.
13) Problem: Outgoing air not hot:
Actions: • Check that the fan is working.
NOTE 1
All signals/warnings remain shown until you intervene on the remote control, by pressing the button .
Do not use the insert before having eliminated the problem.
NOTE 2
Once 1000 kg of pellets have been consumed or some other value set by the CAT during the ¿ rst ignition, the display
À ashes a message that reads “maintenance”.
The stove works, but you must call the Dealer out to perform extraordinary maintenance.
NOTE 3
solid-fue due to the quality of pellets or particularly critical installation, the stove becomes clogged earlier, the message
“CALL SERVICE” will appear. Proceed as per “Mainten.” instructions.
N.B.:
The combustion chambers and smoke ducts connected to the solid-fuel appliances must be cleaned once a year (check
if your country has speci¿ c legislation covering this).
Failure to regularly check and clean increases the likelihood of a ¿ re in the chimney pot.
IMPORTANT!!!
In the case of a ¿ re in the stove, in the À ue or in the chimney, proceed as follows:
- Disconnect the power supply
- Use a carbon dioxide (CO2) extinguisher
- Call the ¿ re brigade
DO NOT ATTEMPT TO PUT THE FIRE OUT WITH WATER!
After the event, have the appliance checked by an authorised Service Centre and have an authorised technician check the À ue.
43

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin Ania Air Tight wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Edilkamin Ania Air Tight

Edilkamin Ania Air Tight Bedienungsanleitung - Deutsch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info