Filling the feed screw
If the pellet storage tank is completely emptied, it follows that the Archimedes' screw is also emptied. Before restarting the stove you
must fill it by following these steps: press the +/- keys simultaneously (via the radio control/ remote control or the synoptic panel) for
a few seconds, after which, having released the keys, the display will show the text "Reload".
It is quite normal for some pellet residue to remain inside the hopper, this is what the feed screw is unable to pick up. Once a month,
fully vacuum the hopper to prevent dusty residue from accumulating.
Automatic ignition
With the thermo-stoves on stand-by, press the 0/1 button for 2 seconds (on the synoptic panel or radio control/ remote control). This
will start-up the ignition process, ‘Start’ will appear on the display and a countdown will commence in seconds (1020). There is no
preset time for the ignition process: its duration will be automatically shortened if the control board detects that certain tests have been
carried out positively. The flame appears after about 5 minutes.
Manual ignition(in case of start up failure)
At a temperature lower than 3 °C – too low for the electrical resistance to become red hot - or if the resistance is temporarily not
working, you can use a firelighter to ignite the thermo-stoves.
Insert a well-lit firelighter into the combustion chamber, close the door and press 0/1 on the synoptic panel or radio control/ remote
control.
Operating modes
Operating from synoptic panel/radio control/ remote control. With the thermo-stoves running or on stand-by, from the synoptic panel:
- press the + or – keys to increase or decrease the desired water temperature.
- by pressing the key you can change the SET temperature of the boiler or of the secondary circuit in general, using the +/-
keys. It is possible to visualise (if the boiler probe is connected) the temperature of any boiler/external storage, by pressing the "boi-
ler" key the set value is displayed, by pressing the +/- keys while viewing the boiler value set that setting can be varied. If the boiler
probe is not connected dashes appear in place of the temperature (--.-° C).
Shutdown
While the stove is working pressing the 0/1 key for 2 seconds begins the shutdown process and "OFF" is displayed (for 10 minutes).
The turning off phase includes:
-The interruption of falling pellets
-The circulation of running water.
Never pull the plug during shutdown.
N.B.Please note that the circulator runs until the water temperature drops below 40° C.
Setting the clock
Press the MENUbutton for 2 seconds and use the + and – keys to follow the instructions given on the display to access the ‘Clock’ menu.
This allows you to set the time on the electronic control board. Then press MENUand the following data appears in sequence – this
can be adjusted: day, month, year, hour, minutes, day of the week. When ‘Save?’ appears on the display, you can check that the set-
tings have been entered correctly before confirming. Press MENUto save the information (‘Save OK’ then appears on the display).
Programmer to ignite and shutdown the thermo-stoves at various times during the week.
Press the MENU button on the radio control/ remote control for 2 seconds to access the time setting function and press the + key to
access the weekly timer function ‘Program ON/OFF’ will appear on the display.
The timer allows you to set a number of ignitions and shutdowns per day (up to a maximum of three), for each day of the week. As
you confirm via the MENUbutton, one of the following options will appear:
- No Prog. (no program is set)
- Program/daily (a single program is set for every day)-
- Program/weekly (a program is set for each day of the week)
Move from one to the other using the + and – keys.
Use the MENUbutton to confirm the ‘Daily program’ option and access the selection of the number of programs (ignition/shutdown) to be set per day.
Use the ‘Program/daily’ option to set the identical program/s for every day of the week.
The following will be displayed if the + key is pressed:
- No Prog.
- Prog. No. 1 (one ignition and one shutdown per day), Prog. No. 2 (same as before), Prog. No. 3 (same as before)
Use the button to show them in reverse order. If the 1st program is selected, the ignition time is shown.
The display shows: 1 Ignition Hour 10.30; use the +/– keys to change the hour and press MENUto confirm.
The display shows: 1 Ignition Minutes 10.30; use the +/– keys to change the minutes and press MENUto confirm.
In the same way, adjust the shutdown times.
The program is confirmed by pressing the MENUbutton when “Saved” appears on the display.
When confirming ‘Program/week’, you will need to choose the day to which the program is to apply:
INSTRUCTIONS FOR USE
44

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin ATLANTA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info