ENGLISH
HYDRAULIC CONNECTIONS
The hydraulic connections depend on the type of
system.
However, there are a few “general rules”.
Below are the reference rules according to the Italian
standards:
The plumbing connections must be made by
qualified personnel who can issue documentation
certifying the correct installation according to the
regulations in force in each country (for example,
in Italy pursuant to Ministerial Decree 37/2008
and pursuant to the UNI 10412-2 standard).
The hydraulic system must operate at a pressure
between 1 and 1.5-2 bars at running temperature
(hot) in a closed vessel circuit.
N.B.: the product SHOULD NOT be installed in
place of, for example, an open-vessel installed
cooker without adjusting the expansion system
to closed vessel.
The presence of a puffer (inertial storage
tank) is recommended but not mandatory. Its
advantage is that it releases the product from
“sudden” requests from the system and can be
integrated with other heat sources. It reduces
fuel consumption and increases the efficiency of
the system.
The return temperature of water must be higher
than at least 50–55°C to prevent condensate from
forming. The installer must assess, in relation to
the plant, whether anti-condensate pumps or
valves are required.
An accumulator (tank) is needed to heat low-
temperature radiant panels and must be
installed according to the panel manufacturer’s
instructions. Radiant panels must not receive
water directly from the boiler stove.
The material used in the circuit must be suitable
to withstand overheating.
The safety valve’s relief outlet must be accessible
and visible. Waste water must be conveyed via a
vertical pipe through a funnel with backflow air
vents, at a suitable distance from the point of
drainage.
IT IS FORBIDDEN TO SHUT OFF THE OUTLET
HYDRAULIC INSTALLATION
INSTALLER
All local, national laws and European Standards must
be met in the proper sizing, installation, maintenance
and use of the appliance. Refer to local codes in
each country for installation and for anything not
specifically mentioned.
Any disabling can be made into the installer
parameters.
• C
heck that the hydraulic system has been properly
arranged and that it is equipped with a sufficiently
large expansion vessel for guaranteeing its safety.
The presence of the vessel incorporated in the
boiler stove does NOT guarantee adequate
protection against thermal expansion of the water
in the entire system. Therefore, installers should
assess whether an additional expansion tank is
needed, depending on the type of system.
The installer must assess, on the basis of the type
of water and system, whether water conditioners
are required pursuant to the UNI 8065 standard
(water treatment in heating systems for civil use).
Direct plumbing to the radiators prevents proper
operation, owing to the small diameter of their
pipes.
Fill the system via the filling valve (we recommend not
exceeding a pressure of 1.5 bar).
During the filling phase, bleed the pump and the relief
valve.
Pressure gauge
The boiler stove has an electronic system for reading
the water pressure. There is no analogue pressure
gauge. The water pressure is shown on the display, in
the middle as shown in the diagram below.
M®Ä
T«
14,9°C
18:02
20
1,2 bar
The return water temperature must be at
least 50-55° C to avoid condensation. An
anti-condensation system is essential,
under penalty of forfeiture of warranty,
as installation is not correct and non-
compliant.
35

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin Blade H 15 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Edilkamin Blade H 15

Edilkamin Blade H 15 Bedienungsanleitung und Installationsanweisung - Deutsch - 88 seiten

Edilkamin Blade H 15 Bedienungsanleitung und Installationsanweisung - Französisch - 88 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info