29
8.3. Positioning on the floor
The product does not have feet.
You can consider adding felt pads to ensure easier sliding of the product
8.4. Preliminary remarks on installation
Remember that:
The installation must be performed by qualified personnel;
All local and national laws and European Standards must be complied with when installing and using the product.
In Italy the reference is the standard UNI 10683;
In the case of installation in condominiums it is necessary an offer with positive recommendation of the
administrator;
In the case of installation in public places, check and comply with local regulations for these installations.
The product is designed to operate in all weather conditions. In case of special conditions, as strong wind, safety
systems may intervene forcing the switch off of the product. (if any)
Some indications of a general nature are given below, which do not replace the checking against the local standards
and do not bring any liability concerning the installer’s work.
8.5. Checking the suitability of the installation room
The volume of the room must be greater than that indicated in the technical table
The floor must be able to support the weight of the product and its accessories* (see the note in the paragraph
on heat protection)
Make sure that the product is levelled
Do not install in rooms where there is a risk of fire or explosion.
In Italy, check compatibility pursuant to UNI 10683 and UNI 7129 in the presence of gas products.
8.6. Heat protection and safety distances
All the surfaces of the building adjacent to the product must be protected against overheating.
The insulation measures to be taken depend on the type of surfaces present.
The product must be installed in accordance with the following safety conditions:
Minimum distance from any combustible materials: see the declaration of performance on the website
The diameter of the smoke outlet is not the diameter of the chimney system. The chimney
system must be sized according to national and local regulations.
In particular, (non-exhaustive list) refer to EN 13384, EN 1443, EN 1856, EN 1457 and to all local
regulations.
In some countries, in special conditions, multiple chimney flue installations are allowed.
According to regional regulations, additional safety systems are required when connecting to
multiple chimney flues. Your chimney sweep/technician is available for further information.