FIRE DAMPERS
The re damper should be easily handled and its position must be distinguished from the outside through the adjustment knob.
The re damper must remain xed in its position and must not be able to close automatically.
The re dumper must NOT close the ue section completely, but it must guarantee a permanent minimum opening which should
be equal to 3 % of the section itself and in any case equal to at least 20 cm2.
CHIMNEY POT
The
of the ue, and smoke outlet cross-section at least twice that of the internal ue cross-section.
For correct operation, please refer toUNI 10683/2005.
AIR INTAKE
The room of installation must have a suitable outside air intake with a through surface area of at least 200 cm2 (Ø 16), in order to
replenish the burnt oxygen and ensure an adequate combustion air ow.
SAFETY DISTANCES
te
to these distances ensures efcient ventilation and improves thermal efciency.
- In the event the stove is to be installed on a oor made with a ammable material, we recommend placing it on a steel plate
available as an optional.
EDILKAMIN declines any responsibility for installations not complying with the laws in force and for misuse of the stove.