ENGLISH
20
GENERAL SAFETY REGULATIONS
• THE THERMO FIREPLACE MUST NEVER
FUNCTION WITHOUT WATER IN THE SYSTEM.
• THE THERMO FIREPLACE CAN BE DAMAGED IF IT
IS IGNITED WITH NO WATER IN THE SYSTEM.
• The thermo fireplace is designed to heat water by
means of wood combustion in the hearth.
• The only hazards that can derive from using the
thermo fireplace pertain to non-compliance with the
installation instructions, direct contact with live
electrical parts (inside), contact made with the fire and
hot parts or foreign substances being put in the
fireplace.
• For the thermo fireplace to function properly
installation must be carried out according to the
instructions given in this booklet and the door must
only be opened to refill the hearth with wood.
• Never put foreign substances in the hearth or in the
tank.
• No flammable products are to be used to clean the
smoke outlet channel.
• The glass can be cleaned when COLD with a suitable
product (e.g. GlassKamin) and a cloth. Do not clean
when hot.
• The exhaust pipes and the door become very hot
when the thermo fireplace is used.
• Do not place anything that is not heat resistant close to
the thermo fireplace.
• NEVER use liquid fuel to ignite the thermo fireplace or
to rekindle the embers.
• Do not obstruct the external air inlets in the room
where the fireplace is installed or the air inlets of the
thermo fireplace itself.
• Do not wet the thermo fireplace and do not go near the
electrical parts of the system with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The thermo fireplace must be installed in a place that
is suitable against fire hazards and equipped with all
that is required (power and air inlets/outlets) for it to
function properly and safely.
• The thermal relief valve (supplied by Italiana Camini) must be connected to
the cooling circuit with a minimum pressure of 1.5 bar.
AL=P= coil power supply, always with a minimum pressure of 1.5 bar
• KITS 5 and 6 must be installed within a MAX distance of 150 cm from the
fireplace.
• Another expansion tank must be installed specifically for the thermo
fireplace in accordance with the volume of water of the system.
• The safety valve and the thermal relief valve must be checked at least once a
year by qualified personnel in accordance with Italian Law No. 46/90
Litres ?
1 Year
MAX 1,5 m
NO YES
ONLY THERMO FIREPLACES THAT HAVE A THERMAL RELIEF VALVE WHICH
ACTUATES THE COIL CAN BE INSTALLED ON CLOSED TANK SYSTEMS
Installations with a closed tank:
• The installer is responsible for the correct installation of the system, which is
to be compliant with UNI standards 10683/2005 – 9615/90 – 10412:2
• The entire process must be carried out by qualified personnel in accordance
with Italian Law No. 46/90
(VALID ONLY FOR IDRO 50/CS)
MIN.
1,5 bar