Kit N3 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product to
be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted by the
fireplace.
KIT N3 code 627690
Components KIT N3
CA: Wall Mounted Boiler
PR: Pump (circulator)
P1: Primary circuit pump
RE: Electronic regulator
TA: Room thermostat
VE: Expansion Tank
Ja: Air refief Valve
V: Intercept valve
VR: Retaining valve
ST: Temperature Sensor
F: Flow switch
Sc: Heat plate exchanger
EV: 3-way solenoid valve
RI: Heating system return
RA: Radiators
MI: Heating system flow
AF: Cold water
ACS: Hot sanitary water
S: Drain
SYSTEM FOR AN OPEN TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACEITH HOT SANITARY WATER PRODUCTION AND A WALL MOUNTED BOILER USING KIT N3
Heating system return G 3/4”
EDILKAMIN generator flow G 3/4”
EDILKAMIN generator return G 3/4”
Heating system flow G 3/4”
Cold sanitary water inlet G 1/2”
Hot water return to the sanitary system G 1/2”
Safety valve - temperature and pressure (90 °C - 3bar)
Flow Switch
Air relief valve G 3/8”
EDILKAMIN generator circuit circulator
3-way heat exchanger
Intercept valve G 1”
Electronic regulator with wiring
Appropriate aperture for the cable duct to pass through
Power cable
Cables for the heating system circulator (phase, neutral, earth)
Temperature sensor
Room thermostat circuit
1
2
3
4
5
6
7
11
12
13
8
9
10
14
15
16
17
18
KIT N3
Collector
Safety pipe Ø> 28mm
Inlet pipe Ø> 18mm
Electricity
Mains
Water
Mains
Cable duct
circuit connected to
the room thermostat
(implemented by the
client)
must be connected to the
heating system circulator
Electrical Connections
Room thermostat
Electricity
Mains
sensor
Sanitary-heating enabled setting Primary circulator enabled setting
Enabled alarm
Flow sensor
Heating pump
Primary circuit pump
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THIS TO FUNCTION PROPERLY 27