* The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91, and subsequent changes toge-
ther with an expected heat output of 35 Kcal/m³ per hour.
* It is also important to consider the position of the stove in the
room to be heated.
N.B.
1) bear in mind that external devices may cause interference.
2) caution: live parts. Servicing and/or inspections must be carried out by qualied staff.
ELECTRICAL SPECIFICATIONS
Power supply 230Vac +/- 10% 50 Hz
On/off switch yes
Average power consumption 150 W
Power consumption during ignition 400 W
Remote control frequency (optional extra) infrared
Protection on mains power supply * 2A, 250 Vac 5x20 Fuse
Electronic circuit board protection 2A, 250 Vac 5x20 Fuse
SAFETY DEVICES:
THERMOCOUPLE:
On the smoke outlet. It measures the smoke temperature.
It controls the ignition, operating and shutdown stages according to
the parameters set.
AIR FLOW SENSOR:
On the intake duct. It trips when the ow of combustion air is not
correct, therefore causing low pressure problems in the smoke
circuit.
SAFETY THERMOSTAT:
It trips if the temperature inside the stove is too high.
It stops pellet loading, thus causing the stove to go out.
ENGLISH
ENGLISH
HEATING SPECIFICATIONS
Nominal power 8,0 kW
Efciency nominal power 89,2 %
Emissions CO (13% O2) nominal power 75 ppm
Smoke mass nominal power 5,5 g/s
Reduced power 3,4 kW
Efciency reduced power 92,6 %
Emissions CO (13% O2) reduced power 280 ppm
Smoke mass reduced power 2,9 g/s
Maximum overheated smoke 150 °C
Minimum draught 12 Pa
Time between refuellings (min/max) 7,5/18 hours
Fuel consumption (min/max) 0,7/2,0 kg/h
Hopper capacity 15 kg
Heatable room dimensions * 190 m³
Weight including packaging 152 kg
Smoke duct diameter (A male) 80 mm
Air intake duct diameter (B male) 40 mm
The Dealer can install an optional
on the AUX outlet (clean contact
on the pins) for controlling the
process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove. Can
be connected via special optional trestle (code 620550).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt
CR 2032 battery).
Its malfunction is indicated with the following messages:
(not considered a defect but due to normal wear-and-
tear): ERR 1 - ERR 2.
For more detailed information, please contact the DEA-
LER who has performed the rst 1st ignition.
FUSE
* two fuses are inserted on the socket
behind the stove, tted with a switch one
is functional and the other is spare.
*
*