TROUBLESHOOTING
- No depression (trips when the ow sensor detects insufcient combustion air ow)
The ow may be insufcient because the door is open, or does not close tightly (e.g. bad seal), there is an air intake or smoke
extraction problem or the combustion chamber is clogged up.
Check:
- door is closed
- combustion air extraction duct (clean it, taking care not to damage the ow sensor elements)
- ow sensor, cleaning it with dry air (such as that used to clean a PC keyboard)
- stove position: must not be against the wall- combustion chamber position and cleaning (frequency connected with the type of
pellets used)
- smoke duct (clean)- installation (if it does not comply with regulations and has more than 2-3 bends then the smoke outlet is not
acceptable)
- ow sensor threshold (SF in the parameters).
Cold test the sensor if malfunction is suspected. If the value displayed does not vary when the conditions are changed, for example
the door is opened, then the sensor is faulty.
The low pressure alarm may also occur during ignition as the ow sensor starts monitoring 90 seconds after the ignition cycle
starts.
- No expulsion (trips if the smoke extraction revolution sensor detects a fault)
- Check that the smoke extractor is working properly
- Check revolution sensor connection
- Check that the smoke duct is clean
- Stop Fire (trips when the thermocouple detects that the smoke temperature is lower than a set value, interpreting such as the
absence of ame)
The ame may be absent due to:
- a lack of pellets- too many pellets have smothered the ame
- the maximum temperature thermostat has tripped (this is very unusual since it would indicate an excessive smoke temperature)
- Start Fail (trips if no ame appears or the start temperature is not reached within a maximum of 15 minutes).
Distinguish between the following two cases:
NO ame has appeared
A ame has appeared but is displayed after
Start Fail
Check:
- position and cleaning of the combustion chamber
- that the combustion chamber receives combustion air
- that the heating element is working- room temperature
(relighter is required if below 3°C) and humidity.
Try lighting with relighter
Check:
- that the thermocouple is working correctly
- that the start temperature is set within the parameters
- Black-out
Check electrical connection and voltage drops (the block does not depend on the stove).
- Broken TC (trips if the thermocouple is faulty or disconnected)
Check connection between the thermocouple and the circuit board.
Check operation during cold testing
- Over temp exit (shutdown due to excessive smoke temperature)
Excessive smoke temperature may be caused by:
type of pellets, smoke extraction fault, blocked duct, incorrect installation or gearmotor “drift”.
ERROR RTC RD
The heating stove will not stop, but this message appears on the display. The buffer battery on the pcb must be replaced.
Contact the DEALER.
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin marea wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info