ENGLISH
In the event of problems the boiler-stove stops automatically and runs the shutdown pro-
cess and the display shows text regarding the motivation of the shutdown (see the various
alarms below).
Never pull the plug during shutdown on account of malfunction.
To start the boiler-stove up again after a shutdown, let the shutdown procedure end (10
minutes marked by a beep) tand
then press the button .
Do not turn the boiler-stove on again before checking the cause of the malfunction and
CLEANING/ EMPTYING the crucible.
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION AND INDICATIONS AND REMEDIES
(shown only on the control panel on board the boiler-stove):
1) Signalling: H1 (take action if the water temperature sensor is out of order or disconnected).
Problem: Shuts down due to the water temperature sensor being broken or discon-
nected.
Actions: - Check connection of the sensor to the control board.
- Verify functionality by means of a cold test
2) Signalling: H2 Failure of fume expulsion motor (this trips if the smoke extraction speed sensor
detects a fault)
Problem: Shutdown for smoke extraction speed fault detection
Actions: • Check smoke extractor function (devolution sensor connection) and board (DEALER).
• Check smoke channel for dirt
• Verify the electrical system and earthing system.
• Check eletronic circuit board (DEALER).
3) Signalling: SF (H3) Stop/Flame: (this trips if the thermocouple detects a smoke temperature lower
than the value set, which it interprets as the absence of flames)
Problem: Turns off due to drop in smoke temperature
Flame may fail for any of the following reasons:
Actions: - lack of pellets
- too many pellets have suffocated the flame, check pellet quality (DEALER)
• Check whether the maximum thermostat has caused the problem (rare circumstance since this
would
correspond to over heated fumes (technical assistance centre)
• Check whether the pressure switch has cut off electricity to the gear motor because of a blocked
flue or other
problem.
4) Signalling: AF (H4) Failed ignition (intervenes if a flame fails to appear within a maximum of 15 minu-
tes, or if ignition temperature is not reached).
Problem: Turns off due to incorrect smoke temperature during ignition
Distinguish either of the following cases:
Flame does NOT appear
Actions: Check: - combustion chamber position and cleanliness;
- arrival of combustion air in the combustion chamber;
- if the heating element is working (DEALER);
- room temperature (if lower than 3°C use a firelighter) and damp.
- Try to light with a firelighter.
Flames appear, but AF appears on the display after Ar.
Actions: Check: (only by the Dealer)
- if the thermocouple is working (DEALER);
- start-up temperature setting in the parameters (DEALER).
5) Signalling: H5 black out stop (not a defect of the boiler-stove).
Problem: Turns off due to lack of electricity
Actions: • Check electricity connection and drops in voltage.
6) Signalling: H6 broken or disconnected thermocouple
Problem: Turns off due to thermo coupling failed or disconnected
Actions: • Check connection of thermo coupling to board: Check function in cold test (DEALER).
TROUBLESHOOTING
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin Mito Idro wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Edilkamin Mito Idro

Edilkamin Mito Idro Bedienungsanleitung und Installationsanweisung - Deutsch - 36 seiten

Edilkamin Mito Idro Bedienungsanleitung und Installationsanweisung - Holländisch - 32 seiten

Edilkamin Mito Idro Bedienungsanleitung und Installationsanweisung - Französisch, Italienisch - 68 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info