ADVICE IN THE EVENT OF PROBLEMS (for the DEALER)
1) Check/Air flow (trips when the flow sensor detects insufficient combustion air flow).
The flow may be insufficient because the door is open, or does not close tightly (e.g. bad seal), there is an air intake or
smoke extraction problem, the combustion chamber is clogged up or the flow sensor is dirty (clean with dry air).
Check the flow sensor threshold (in the dealer parameters).
The depression alarm may also occur during ignition.
2) Check/Expulsi (trips if the smoke extractor revolution sensor detects a fault)
- check that the smoke extractor is working properly (revolution sensor connection)
- check that the smoke duct is clean
- check the electrical system (earthing)
3) Stop/fire (trips when the thermocouple detects that the smoke temperature is lower than a set value, interpreting
such
as the absence of flame)
The flame may be absent due to:
- a lack of pellets
- too many pellets have smothered the flame
- the maximum temperature thermostat has tripped (this is very unusual since it would indicate an excessive smoke
temperature)
4) BloccoAF/No start (trips if no flame appears or the start temperature is not reached within a maximum of 15 minu-
tes). Distinguish between the following two cases:
5) Black-out
Check electrical connection and voltage drops.
6) Broken/TC (trips if the thermocouple is faulty or disconnected)
Check connection between the thermocouple and the circuit board: check operation during cold testing.
7) OverTemp/exit (shutdown due to excessive smoke temperature)
Excessive smoke temperature may be caused by: type of pellets, smoke extraction fault, blocked duct, incorrect
installation, gearmotor "drift" or lack of air intake in the room.
8) STOP FANFRONT (shutdown due to an anomaly in the front fan)
- verify front fan functionality
- verify control board functionality
- verify electrical system (earthing system)
9) STOP FANCNLZ (shutdown due to an anomaly in the channelling fan)
- verify channelling fan functionality
- verify control board functionality
- verify electrical system (earthing system)
OTHER PROBLEMS
(for the DEALER)
• The differential “blows” during ignition: check the humidity level of the ignition element.
“Error rtc-rd”: Indicates the backup battery to be replaced
USER NOTES
In the event of problems that cannot be resolved directly or for any kind of complaint please contact the Dealer that
performed the installation and/or the dealer quoting the contents slip number and the purchase document reference
number.
NO flame has appeared
A flame has appeared but Start Failed has been
displayed after BloccoAF/No start
Check:
• position and cleaning of the combustion chamber
• ignition element works correctly
• room temperature (firelighter is required if below 3°C)
and humidity. Try lighting with firelighter.
Check that:
• the thermocouple is working correctly
• the start temperature is set within the parameters
ENGLISH
sk tecnica soleil-polaris-tania multilingua_fra ristampa febbraio 2010.qxp 24/02/2010 9.10 Pagina 47
46

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin POLARIS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Edilkamin POLARIS

Edilkamin POLARIS Bedienungsanleitung - Deutsch - 48 seiten

Edilkamin POLARIS Bedienungsanleitung - Holländisch - 34 seiten

Edilkamin POLARIS Bedienungsanleitung - Spanisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info