810759
30
Zoom out
Zoom in
Vorherige Seite
1/56
Nächste Seite
30
In the case of installation with a wall made of wood or other flammable material, the smoke exhaust pipe must be
adequately insulated.
In the case of installation on a floor made of flammable and/or combustive material or with an insufficient load-bearing
capacity, it is advisable to place the product on a load distribution plate.
8.7. Chimney system (Smoke duct, chimney flue and chimney pot)
This chapter is written in accordance with European Standards EN 13384, EN 1443, EN 1856, EN 1457.
The installer must take these Standards and any other local regulations into account.
This manual is in no way to be considered as a replacement for current regulations.
The product must be connected to a suitable smoke exhaust system that guarantees the safe and complete
evacuation of the smoke produced by combustion.
Before positioning the product, the installer must make sure that the chimney flue is suitable.
8.8. Smoke duct, chimney flue
The smoke duct (duct connecting the fire box smoke outlet to the chimney flue inlet) and the chimney flue must,
among other regulatory requirements, in general:
Receive the smoke coming from only one product (it cannot receive the smoke coming from several products);
in some countries there are specific regulations: it is the responsibility of the installer to assess compliance with
local regulations.
Have a predominantly vertical development.
Not have any counter-sloping sections.
Have a preferably circular inner cross-section and in any case with a ratio between sides of less than 1.5.
End on the roof with a suitable chimney pot: it is forbidden to discharge directly from the wall or towards enclosed
spaces, even if outdoors.
Be made of materials with fire reaction class A1 pursuant to UNI EN 13501 or similar national Standard.
Be suitably certified, with an appropriate chimney plate if metal.
Maintain the initial section or vary it only immediately above the product outlet and not along the chimney flue
8.9. Smoke duct
If in metal, it must be provided with CE marking (EN 1856-2) or similar national legislation;
It cannot be made of flexible metal material
To control the flow we recommend a damper in case of high draft
8.10. The chimney flue
In addition to the general requirements applicable to the smoke duct and to the chimney flue, the chimney flue:
Must only be used to discharge smoke.
Must be correctly sized to meet smoke evacuation requirements (EN 13384-1 non-exhaustive example)
Is preferably insulated, made of steel and with a circular inner cross-section. If rectangular, the edges must
normally have a radius of not less than 20 mm and a ratio between internal dimensions <1.5.
Normally have a minimum height of 1.5 metres.
Maintain a constant cross-section.
Be waterproof and thermally insulated to ensure draught.
Preferably have a collection chamber for unburnt material and any condensation.
If pre-existing, it must be cleaned, to avoid fire hazards.
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin Polo Open Evo wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Edilkamin Polo Open Evo

Edilkamin Polo Open Evo Bedienungsanleitung und Installationsanweisung - Deutsch - 56 seiten

Edilkamin Polo Open Evo Bedienungsanleitung und Installationsanweisung - Holländisch - 56 seiten

Edilkamin Polo Open Evo Bedienungsanleitung und Installationsanweisung - Französisch - 56 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info