810875
31
Zoom out
Zoom in
Vorherige Seite
1/158
Nächste Seite
ENGLISH
30
FEATURES
* The heatable room dimensions are calculated on the basis of pellets with an lhv of at least 4300 kcal/kg and home insulation in compliance
with Italian law 10/91, and subsequent changes together with an expected heat output of 33 Kcal/m³ per hour.
It is also important to consider the position of the thermo-stoves in the room to be heated.
A LOT DEPENDS ON THE EFFICIENCY OF THE SYSTEM TERMINALS (heaters).
N.B.
1) Bear in mind that external devices may cause interference.
2) Warning: work on live components, maintenance and /or checks must be performed by qualified personnel.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
ELECTRICAL CHARACTERISTICS
Power supply 230Vac +/- 10% 50 Hz
On/off switch yes
Average power consumed 120 W
Average power consumed upon ignition 400 W
Radio control / Remote control frequency Radio waves 2.4 GHz / Infrared
Main power supply protection ** ** Fuse 2A, 250 VAC 5x20
Electronic control board protection ** Fuse 2A, 250 VAC 5x20
SERIAL PORT
The Dealer can install an optional on the AUX outlet for controlling the process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove. Can be connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032 battery). Its malfunction is indicated with the following messages
(not considered a defect but due to normal wear-and-tear): “Battery Check”.
For more detailed information, please contact the DEALER who has performed the first 1st ignition.
The data shown above is purely indicative.
EDILKAMIN reserves the right to make changes to these products to improve their performance with no prior warning.
SAFETY DEVICES
**
FUSE**
two fuses are inserted in the soc-
ket with switch, located on the
back of the stove, one of which
operational and the other is held
in reserve.
THERMOCOUPLE:
placed at the smoke outlet to detect the temperature. Turns the thermo-stoves on and off and
controls its operation based on defined parameters.
VACUUM GAUGE (electronic pressure sensor):
positioned on the smoke extractor, which detects the vacuum value (compared to the
installation environment) in the combustion chamber.
WATER SAFETY THERMOSTAT:
trips when the temperature inside the thermo-stoves is too high.
It stops pellet loading, causing the thermo-stoves to go out. Reset manually.
TANK SAFETY THERMOSTAT:
trips when the temperature inside the thermo-stoves is too high.
It stops pellet loading, causing the thermo-stoves to go out.
TECHNICAL AND HEATING SPECIFICATIONS
QUEBEC/ TORONTO/MONTREAL DETROIT/ BOSTON/MIAMI OTTAWA ATLANTA
Hopper capacity 60 60 100 100 kg
Approx. overall efficiency 93,3 93,2 91,9 91,2 %
Rated power 24 32,6 24 32,3 kW
Water heating power 21 29,3 24 32,3 kW
Min./max. autonomy 11 / 38 8 / 26 18 / 65 13/ 44 hores
Fuel consumption min./max. 1,5 / 5,4 2,2 / 7,3 1,5 / 5,4 2,2 / 7,4 kg/h
Minimum draught 12 / 5 12 / 5 12 / 5 12 / 5 Pa
Max. pressure 3 3 3 3 bar
Operating pressure 1,5 1,5 1,5 1,5 bar
Smoke output temperature from test EN14785 114 142 97 142 °C
CO emission (13% O2) 0,011 0,012 0,013 0,013 %
Weight including packing 390 / 370 / 360 390 / 370 / 359 355 370 kg
Heating capacity * 625 850 625 840 m3
Diameter of smoke extract duct male thread 10 10 10 10 cm
31

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin QUEBEC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info