810875
36
Zoom out
Zoom in
Vorherige Seite
1/158
Nächste Seite
ENGLISH
35
HYDRAULIC CONNECTIONS
(Reserved for DEALER)
The stoves have a boiler with a capacity of 80 Lts. of water. This significant amount of water renders the stove extremely smooth in
operation, little affected by variations in demand of users. This will provide for highly consistent combustion with excellent yield .
The stoves are equipped with a kit for producing instant Domestic Hot Water for bathrooms and kitchens as well as kits for the hea-
ting system (circulator, safety, loading and unloading). The stoves are also equipped with a solenoid valve that, in the start-up phase
plays a very useful RECIRCULATION function; moving the water inside the stove, and speeding up the heating phase.
The hydraulic connection must be performed by qualified personnel who can issue a declaration of conformity according to the
Ministerial decree no. 37 ex L.46/90. Reference must however be made to the laws in force in the individual countries.
Water treatment
Foresees the addition of antifreeze, de-scaling and corrosion substances. In the event that the water used for filling and toping up has
a hardness greater than 35° F, use a water softener. For suggestions please refer to regulation UNI 8065-1989 (Water Treatment In
Heating Systems For Civil Use).
The following is a schematic diagram of the hydraulic kit built into the stove for instant production (without accumulation) of ACS.
Circulator
The Ottawa is equipped with a circulator with a new
generation electronic motor.
3-way valve
Safety Valve
Flow meter
Plate heat exchanger
THE ELECTRONIC CIRCULATOR
The Ottawa is equipped with a circulator with a new generation electronic
motor.
Electronic control of operation:
a) Control mode Δp – c
In this mode, the electronic controller keeps the differential pressu-
re generated by the pump at a constant set value of H s.
b) Control mode Δp – v
In this mode, the electronic controller varies the pressure differential between
the set value Hs and 1/2 Hs. The pressure differential varies with the volume
flow.
c) Venting procedure
This procedure allows the expulsion of air present in the hydraulic circuit.
After manual selection of the "AIR" mode, the pump will automatically alter-
nate between maximum and minimum speed for 10 minutes. At the end of the
procedure, the circulator will go to the pre-set speed. You can then select the
desired mode of operation
Pressure differential
Volume flow
Pressure differential
Volume flow
36

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin QUEBEC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info