ASSEMBLYAND INSTALLATION (Dealer)
Refer to the local regulations in the country of use for anything not expressly shown. In Italy, refer to UNI standard
10683/2005, along with any regional or local health authority regulations. If the stove is to be installed in a block of
flats or jointly owned property, consult the administration before installing.
COMPATIBILITYCHECK WITH OTHER DEVICES
The stove must NOT be installed in the same room as extractor fans, type Aand B gas equipment, or devices which
lower the pressure in the room (refer to Italian standard UNI 10683/2005).
ELECTRICALCONNECTION CHECK (the plugg must be in an accessible place)
The stove is fitted with an electrical power cord for connection to a 230 V50 Hz socket, preferably protected with a ther-
mal-magnetic circuit breaker. Voltage variations of greater than 10% may impair stove operation (if not already instal-
led, fit a suitable residual current circuit breaker). The electrical system must comply with the law; in particular make
sure the earth circuit is in working order. The power supply line must have a suitable cross-section for the equipment
rating. An inadequate earthing system can cause anomalies for which Edilkamin cannot be held liable.
FIRE SAFETYDISTANCES AND LOCATION (fig. 4 p. 18)
For correct operation the stove must be level.
Check the load-bearing capacity of the floor.
The stove must be installed in compliance with the following safety conditions:
- minimum safety distance at the sides and back from medium-level flammable materials: 40 cm
- easily flammable materials must not be located less than 80 cm from the front of the stove
- if the stove is installed on a flammable floor, a sheet of heat insulating material must be placed between the stove
and the floor, which protrudes by at least 20 cm at the sides and 40 cm at the front.
If it is impossible to comply with the distances given above, technical/building measures must be taken to avoid all
fire risks.
If the smoke outlet pipe is connected to walls made of wood or other flammable materials, it must be insulated with
ceramic fibre or other materials with similar characteristics.
AIR INTAKE
The room where the stove is located must have an air intake with cross section of at least 80 cm2 to ensure replenishment
of the air consumed by combustion.
Alternatively, the stove air may be taken directly from outside through a 4 cm steel extension of the pipe. In this case,
there may be condensation problems and it is necessary to protect the air intake with a grille, which must have a free section
of at least 12 cm2. The pipe must be less than 1 metre long and have no bends.
It must end with a section at 90° facing downwards or be fitted with a wind guard.
SMOKE OUTLET
The stove must have its own smoke outlet (it must not discharge into flues shared with otherdevices).
The smoke leaves the stove through the 8 cm diameter pipe at the back.
AT-section with condensation trap and bleeder must be fitted at the beginning of the vertical section.
The stove smoke outlet must be connected with the outside using suitable steel pipes, without obstructions.
The pipe seals must be air-tight. Material that withstands up to 300°C (silicone or high temperature mastic) must be
used to seal and insulate the pipes (if necessary).
The only horizontal section allowed may be up to 2 m long. It may have up to two 90° bends.
If the smoke outlet does not end in a flue, a vertical section with wind guard at the end is essential (refer to UNI
standard 10683/2005). The vertical duct section may be indoor or outdoor.
If the smoke duct is outdoor, it must be insulated.
If the smoke duct ends in a flue, the flue must be authorized for solid fuel. If it is more than 150 mm in diameter, it
must be renewed by inserting an internal pipe and sealing the smoke outlet from the brickwork.
All sections of the smoke duct must be inspectable. If it is fixed, cleaning inspection openings must be provided.
Possible installations are shown in figures 1 and 2 on p. 18.
ENGLISH
17
sk tecnica SEVEN multilingua_provvisoria cod 644310.qxp 27/04/2010 16.34 Pagina 18
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin Seven wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info