14
ENGLISH
THE TECHNOLOGY
HOT AIR CIRCULATION DIAGRAM (4 OUTLETS)
outside + indoor
air inlet
hot air outlet
N V
power output kW 18 18,5
wood consumption kg/h 5,4 5,5
efficiency % 72,7 72,7
smoke outlet Ø cm 25 25
Ø stainless steel flue for 5m sup. cm 22 22
Østainless steel flue for 3-5m h cm 25 25
weight including packaging kg 293 303
air intake section cm 300 300
Ø hot air outlet channelling cm 14 14
fan noise level db (A) - 56-58
maximum fan capacity m3/h - 800
heating capacity m3470 480
fan motor power W 90
power supply Vac 230
frequency Hz 50
fuse amperage = see technical specifications sheet attached to the control unit
• AIR INTAKE MECHANISM
the air is drawn in from the outside and mixed with the air
inside using a new wire controlled mechanism recessed in
the bottom front panel of the firebox.
When the fireplace is operating control lever 1bmust be par-
tially or fully positioned to the right (room + outside air).
fitting 4b , the sensor cables and the 230 Vac power supply
can be positioned independently either to the left or to the
right.
hot air outlet
SPECIFICATIONS
****
*
4b
4b
1b
A
C
hot air outlet pipes
230 Vac
power supply
heating air damper control
230 Vac power
supply
Closed
Open
sensor to be placed
on hot air outlet
channel
(see p. 19 fig. O)
sensor