Using the cable clips supplied (Fig. 7), attach
the power cable to the tubes of the push bars
so that it is possible to open and shut the
ejector flap (Fig. 8/Item 10).
Please ensure that the ejector ap can be opened
and closed easily!
Adjusting the scari er depth (see Fig. 9)
The scari er depth is adjusted at both front
wheels via the adjustment mechanism. For this,
pull out the adjusting screw and turn the wheel to
the left or right into one of the available positions
(0/I/II/III).
The scari er depth must always be identically set
on both sides!
0 = drive/transport position
I = scari er depth 3 mm
II = scari er depth 7 mm
III = scari er depth 9 mm
Electrical connection
The equipment can be connected to any normal
socket with 230V AC. It is only acceptable to con-
nect it to a shockproof socket with a 16A circuit
breaker. Furthermore, a residual-current-operated
protective device with max. 30 mA should be con-
nected upstream.
Power cable
Please only use power cables that are not dama-
ged. The total length of the power cable should
not exceed 50 meters; going beyond this distance
will reduce the power output of the electric motor.
The power cable must have a cross-section of 3 x
1.5 mm2. The insulating sheath of scari er power
cables is frequently damaged.
Some of the causes for this are:
Cracking from running over the cable
Pinching when the power cable is dragging
under doors and pulled through windows
Cracking due to old age of the insulation
Kinking by improperly fastening or guiding the
power cable
The power cables must, at the very minimum, be
of type HO5RN-F and 3-stranded. The cable type
must be printed somewhere on the power cable.
Only purchase power cables that are marked as
such! Plugs and socket couplers for the power
cables must be made from rubber and be splash-
proof. There is a limit to how long power cables
can be. Longer power cables require larger con-
ductor cross-sections. Power cables and connec-
ting lines must be regularly checked for damage.
Ensure that the lines are de-energized before
checking them. Completely unwind the power
cable. Also check power cable entry points, plugs
and socket couplers for kinks.
6. Operation
Connect the machine’s power supply cable to the
plug (Fig. 10/Item 1) and secure the power cable
with the stress-relief clip (Fig 10/Item 2).
To prevent accidental start-up of the equipment,
the push-bar (Fig. 11 / Item 5) is equipped with
a safety lock-o (Fig. 11 / Item 2) which must be
pressed before the lever switch (Fig. 11 / Item 1)
can be pressed. If the lever switch is released, the
equipment switches o .
Repeat this process several times so that you are
sure that the machine functions properly. Before
you perform any repair or maintenance work on
the machine, ensure that the cutting unit is not ro-
tating and that the power supply is disconnected.
Important! Never open the ejector ap when the
motor is running. A rotating cutting unit can cause
injuries.
Always fasten the ejector ap carefully. The ap
ips back to the “Closed” position by the tension
springs!
Always ensure that a safe distance (provided
by the long handles) is maintained between the
user and the housing. Be especially careful when
scarifying and changing direction on slopes and
inclines. Maintain a solid footing and wear sturdy,
non-slip footwear and long trousers. Always sca-
rify along the incline (not up and down).
For safety reasons, the scari er may not be used
to scarify inclines whose gradient exceeds 15
degrees.
Use special caution when backing up and pulling
the scari er (tripping hazard)!
Tips for proper working
It is recommended that you overlap scarifying
paths a little.
Try to scarify in straight lines for a nice, clean look.
Insodoing, the aeration swaths should always
overlap each other by a few centimeters in order
to avoid bare strips.
Anl_GC_ES_1231_SPK1.indb 17Anl_GC_ES_1231_SPK1.indb 17 28.08.14 11:1628.08.14 11:16
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell GC-ES 1231 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Einhell GC-ES 1231

Einhell GC-ES 1231 Bedienungsanleitung - Deutsch, Holländisch, Französisch, Italienisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info