3. Proper use
The dehumidi er is designed only for use in pri-
vately used rooms (e.g. living rooms, bedrooms,
bathrooms, storage areas, laundry rooms or
basements).
Note:
65% humidity is the upper limit at which the hu-
man body feels comfortable. If it is too warm for
the human body, the humidity level (i.e. water con-
tent) is too high. Humidity and temperature are
interrelated. A relative humidity (RH) of 35 to 65%
at 21°C is generally considered to be ideal.
It is uneconomical to use the equipment at a room
temperature below 10°C or at a room humidity
below 40%.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Power supply: ..........................220-240 V ~ 50 Hz
Max. rated current consumption: ................ 1.23 A
Starting current: ..............................................9 A
Max. power consumption: .......................... 245 W
Sound pressure level: ......................... 47 dB(A)
Dehumidifying capacity:
.... 0.42 l/h (at a room temperature of 30°C and air
...................................................humidity of 80%)
.... 0.23 l/h (at a room temperature of 27°C and air
...................................................humidity of 60%)
Humidity operating range: .......................... > 40%
Temperature operating range: .................5 – 35°C
Max. volumetric air ow: ........................... 90 m
3
/h
Condensate collector capacity: ..................2 liters
Refrigerant: ................................................R134a
Greenhouse warming potential ...........................
(GWP, kg CO2 eq.) ....................................... 1430
Coolant quantity: ......................................... 130 g
Equipment dimensions:........ 276 x 185 x 470 mm
Equipment weight: ......................................9,9 kg
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Features
The fan and compressor switch o once the pre-
set room humidity has been reached. The fan and
compressor switch on again whenever the preset
room humidity is exceeded.
5.1 Description of the control panel (Fig. 2)
11 LED „Condensate collector full“ (Water full)
12 LED „Voltage present“ (Power)
13 LED „Humidity setting“ (Settings)
14 LED „Timer“ (Timer)
15 LED „Low fan speed“ (Low)
16 LED „High fan speed“ (High)
17 LED indicator
21 ON/O switch (Power)
22 Switch „Humidity setting“ (Settings)
23 Switch „Time setting“ (Timer)
24 Switch „Fan speed”
The following information is displayed in the LED
indicator panel (Item 17):
If the device is supplied with mains voltage,
the prevailing humidity level at the integrated
sensor will be displayed in percent.
The set value is displayed in percent during
the setting of the humidity.
The set value is displayed in hours during the
setting of the timer.
If the prevailing humidity at the integrated
sensor is below 35%, “35” is displayed.
If the prevailing humidity at the integrated
sensor is above 95%, “95” is displayed.
The LEDs shine when the function has been set
(Item 11 – 16).
The device will switch o automatically when the
condensate collector is full.
Provision has also been made for the condensate
to be drained o continuously if preferred.
Anl_LE_10_SPK7.indb 13Anl_LE_10_SPK7.indb 13 03.03.16 08:1403.03.16 08:14
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell LE 10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info