4. Technical data
Power supply: 220 - 240V ~ 50 Hz
Max. rated current consumption: 1.2 A
Max. compressor starting current: 3.4 A
Max. power consumption: 260 W
Sound pressure level: ≤ 45 dB(A)
Dehumidifying capacity:
0.41 l/h (at a room temperature of 30°C and air
humidity of 80%)
0.18 l/h (at a room temperature of 27°C and air
humidity of 60%)
Operating range for humidity 40-90%
Operating range for temperature: 8 -32°C
Max. air flow volume: 100 m
3
Volume of condensate container: 2.0 liters
Coolant: R134a
Refrigerant group: L1
Coolant quantity: 90 g
Appliance dimensions: 500 x 280 x 145 mm
Appliance weight: 7.5 kg
5. Before using
If the switch is “ON”, the dehumidifier is running
continuously.
The unit switches off automatically as soon as the
condensate collector is full.
Constant condensate drainage can be set.
Operating principle
The humid air condenses on the cooler elements and
is transferred to the water tank. The dry air is heated
a little on the condenser and returned to the room. A
refrigerant compressor is needed for operation.
Notes:
The room temperature should lie in the range
from 8 to 32°C. The dehumidifier will not work
effectively outside this range.
To achieve an optimum circulation of air it is
recommended that the appliance be set up in the
middle of the room as far as possible.
Avoid open windows and doors and entering and
leaving the room frequently, etc.
The appliance must never be used in excessively
dusty rooms or rooms with excessive amounts of
chlorine.
The dehumidifying performance of the appliance
is dependent on the characteristics of the room,
the room temperature and the relative humidity.
If the condensate container is not fitted correctly,
the appliance will not work.
To prevent high starting currents the appliance is
equipped with a restart inhibit which only restarts
the compressor after a delay of 3 minutes.
The appliance can be installed on a flat, stable
surface, free-standing anywhere in the room.
Observe the minimum separation distances.
6. Using for the first time
To switch on/off (Fig. 1)
Check that the voltage from the mains power supply
is the same as the voltage indicated on the rating
plate. Connect the plug to the 230 V ~ 50 Hz power
socket.
To switch the appliance on, turn the switch (2) to
“ON”. To switch off, turn the switch to “OFF”.
6.1.1 Operation with condensate collector
Take care during operation of the condensate
collector (5) that the rubber stops on the underside of
the appliance are firmly attached to the drainage for
the hose connection. Otherwise there may be water
loss on the underside of the appliance (Water
damage).
Emptying the Condensate collector (5)
If the condensate collector is full, the appliance
switches itself off automatically and the LED
indicating “Condensate reservoir full” (3) lights up.
Remove the condensate collector by pulling it
sideways out of the housing, then empty it. After
emptying the collector, insert this again in the correct
position
Note:
If the tank is not inserted correctly the “Condensed
water tank full” LED will continue to shine.
6.1.2 Operation with water drainage hose
(Fig. 2 – 4)
1. Press the fastening clamp (A) together and cover
with a fitted water drainage hose of interior
diameter 10mm. The fastening clamp is designed
for hoses with an external diameter of approx.
13mm. For other hoses, please use an
appropriate hose clamp.
2. Insert the pressure spring (B) with the narrower
end into the hose.
Anleitung_LEF_10_M_SPK7:_ 19.01.2011 8:46 Uhr Seite 11
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell LEF 10M wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info