3. Technical data
Cooling capacity 3,500 watts
Heating capacity 3,700 watts
Energy efficiency A (EER 3.27/COP 3.46)
Air capacity 500 m
3
/h
Absorbed humidity 1.0 l/h
Timer 24 h
Operating voltage 220 - 240/50 V ~ Hz
Nominal power consumption, cooling 1,440 watts
Nominal current consumption, cooling 6.26 A
Nominal power consumption, heating 1,440 watts
Nominal current consumption, heating 6.26 A
Compressor Rotary piston
Starting current 30 A
Outdoor temperature, cooling operation °C +21 - +43 (DB)
Outdoor temperature, heating operation °C 0 - + 24 (DB)
Fluid line Ø A 6 mm
Suction pipe Ø A 12 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 1,400 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 40 dB (A)
Outside ≤ 54 dB (A)
Dimensions
Inside 100,5 x 29 x 15 cm
Outside 84,8 x 54 x 32 cm
Weight
Inside 11 kg
Outside 36 kg
Note:
The specified capacities and performances are based on the following conditions (ISO 5151):
Cooling:
Air temperature at the inlet on the indoor device: 27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature: 35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device: 20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature: 7°C for dry thermometer bulb (DB), 6°C for wet thermometer
bulb (WB).