605882
10
Zoom out
Zoom in
Vorherige Seite
1/64
Nächste Seite
10
GB
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection 230V ~ 50 Hz
Power rating 750 W
Max. pumping rate 16,000 l/h
Max. delivery head 7 m
Max. immersion depth 5 m
Max. water temperature 35 °C
Hose connection ca. 47,8 mm (G11/2) female thread
Max. size of foreign bodies: Ø 25 mm
Switching point height: ON max. approx. 62 cm
Switching point height: OFF min. approx. 5 cm
5. Before putting the equipment into
operation
5.1 Installation
The equipment can be installed either:
Stationary with rigid tubing
or
Stationary with a flexible hose line
Note:
The maximum pumping rate is possible only with the
largest possible line diameter; if smaller hoses or
tubes are connected, the pumping rate will be
reduced. If the universal hose connection (Fig. 1/Item
3) is used, it should be shortened (as shown in Fig. 4)
to the connection actually used in order not to reduce
the pumping rate unnecessarily. Flexible hoses must
be fastened to the universal hose connection with a
hose clip (not included in the scope of supply).
Note!
When installing, never hang the equipment by the
discharge line or by the power cable. The equipment
must be hung up with the provided carry handle or it
must rest on the bottom of the shaft. To ensure that
the equipment works properly, the bottom of the shaft
always must be free of sludge and other
accumulations of dirt. If the water level is too low, the
sludge in the shaft can quickly dry out and hinder the
equipment from starting. It is necessary therefore to
check the equipment regularly
(carry out trial start-ups).
Note:
The pump shaft should measure at least
40 x 40 x 50 cm so that the floating switch can move
freely.
5.2 Mains connection
The equipment you have purchased comes with an
earthing-pin plug. The equipment is designed for
connection to a socket outlet with earthing contact for
230 V ~ 50 Hz. Make sure that the socket-outlet is
sufficiently fused (at least 6 A) and in good working
order. Insert the power plug in the socket-outlet and
the equipment is ready for operation.
Important!
To rule out danger, this work must be left strictly to a
specialist electrician or Customer Service.
6. Operation
You can put the equipment into operation after you
have thoroughly read the installation and operating
instructions. Pay attention to the following points:
Make sure that the equipment is set up securely.
Check that the discharge line is fitted correctly.
Make sure that the electrical connection is 230 V
~ 50 Hz.
Check that the electrical socket-outlet is in good
working order.
Make sure that no moisture or water can ever
reach the power connection.
Make sure that the equipment does not run dry.
Setting the ON/OFF switching point:
The ON/OFF switching point can be infinitely
adjusted with the height adjustment facility. For this
purpose you must first slacken the screw (Fig. 2,
Point 6). The switching differential can be infinitely
adjusted by extending or shortening the floating
cable.
The floating switch must be fitted so that the
switching point height: ON and the switch point
height: OFF can be reached easily and with little
force. Check this by placing the equipment in a
container filled with water and carefully raising
and lowering the floating switch with your hand.
You can then see whether the equipment
switches on and off.
Make sure that the distance between the floating
switch head and the cable holder is not too small.
If the distance is too small, there is no guarantee
that the equipment will work correctly.
When adjusting the floating switch, make sure
Anleitung_RG_DP_7525 N_SPK1:_ 16.03.2011 13:05 Uhr Seite 10
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell RG-DP 7525 N wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Einhell RG-DP 7525 N

Einhell RG-DP 7525 N Bedienungsanleitung - Deutsch, Holländisch, Französisch, Italienisch, Portugiesisch, Spanisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info