3
2. Technical data
Cooling capacity 3,500 watts
Heating capacity 3,800 watts
Energy efficiency B (EER 3.02/COP 3.42)
Air capacity 520 m
3
/h
Absorbed humidity 1.3 l/h
Timer 24 h
Operating voltage 230 V ~ 50 Hz
Nominal power consumption, cooling 1,320 watts
Nominal power consumption, heating 1,360 watts
Compressor Rotary piston
Outdoor temperature, cooling operation °C +21 - +43 (DB)
Outdoor temperature, heating operation °C +7 - +24 (DB)
Fluid line Ø A 6 mm
Suction pipe Ø A 12 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 15 m
Max. difference in height between indoor/outdoor device 5 m
Refrigerant R 407 C
Refrigerant filling capacity 900 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 40 dB (A)
Outside ≤ 55 dB (A)
Dimensions
Inside 79 x 27,5 x 18 cm
Outside 83 x 54,5 x 25,5 cm
Weight
Inside 10 kg
Outside 36 kg
Note:
The specified capacities and performances are based on the following conditions (ISO 5151):
Cooling:
Air temperature at the inlet on the indoor device: 27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature: 35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device: 20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature: 7°C for dry thermometer bulb (DB), 6°C for wet thermometer
bulb (WB).