B) Heating mode
1. Press the “ON/OFF” key to switch on the device.
2. Press the “MODE” key until the “Heating” mode icon appears
in the display.
3. Press the “Swing” key. The air flow is adjusted
upwards/downwards. Press the key
twice to lock the slats in their current position.
4. Press the “FAN” key to select the fan speed: Automatic ->
Slow -> Medium -> Fast
5. Press the “+ °C” or “- °C” key to set the desired temperature.
Notes!
The SKA 2502 C does not have a heating mode.
The heating mode will only work if the room temperature set
is higher than the
current room temperature. When the set room temperature
is reached, the
outdoor compressor stops. The centrifugal fan of the indoor
device circulates the
air in the room.
The room temperature can be set between 16 °C and 30
°C with the remote
control.
The attainable room temperature is a factor of local
conditions and the outdoor
temperature. The cooler the outdoor temperature, the lower
the attainable room
temperature.
3
2
1
4
C) Dehumidifying mode
1. Press the “ON/OFF” key to switch on the device.
2. Press the “MODE” key until the “Dehumidifying” mode icon
appears in the display.
3. Press the “Swing” key. The air flow is adjusted
upwards/downwards. Press the key
twice to lock the slats in their current position.
4. Press the “+ °C” or “- °C” key to set the desired temperature.
Notes!
The “Dehumidifying” mode only works if the difference
between the set room temperature and the current room
temperature is within +/- 2 °C.
If the room temperature set for the “Dehumidifying” mode is
more than 2 °C higher than the current room temperature,
the compressor stops along with the fan in the outdoor
device. The centrifugal fan of the indoor device is also
switched off.
If the room temperature set for the “Dehumidifying” mode is
more than 2 °C below the current room temperature, the
device runs in cooling mode.
The room temperature can be set between 16 °C and 30
°C with the remote control.